Semiautomated Volumetric Measurement on Postcontrast MR Imaging for Analysis of Recurrent and Residual Disease in Glioblastoma Multiforme

被引:57
作者
Chow, D. S. [1 ]
Qi, J. [1 ]
Guo, X. [1 ]
Miloushev, V. Z. [1 ]
Iwamoto, F. M. [2 ]
Bruce, J. N. [3 ]
Lassman, A. B. [2 ]
Schwartz, L. H. [1 ]
Lignelli, A. [1 ]
Zhao, B. [1 ]
Filippi, C. G. [1 ]
机构
[1] Columbia Univ, Coll Phys & Surg, Dept Radiol, New York, NY USA
[2] Columbia Univ, Coll Phys & Surg, Dept Neurol, New York, NY USA
[3] Columbia Univ, Coll Phys & Surg, Dept Neurosurg, New York, NY USA
关键词
RESPONSE EVALUATION CRITERIA; SOLID TUMORS; SURVIVAL; GLIOMAS;
D O I
10.3174/ajnr.A3724
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
BACKGROUND AND PURPOSE: A limitation in postoperative monitoring of patients with glioblastoma is the lack of objective measures to quantify residual and recurrent disease. Automated computer-assisted volumetric analysis of contrast-enhancing tissue represents a potential tool to aid the radiologist in following these patients. In this study, we hypothesize that computer-assisted volumetry will show increased precision and speed over conventional 1D and 2D techniques in assessing residual and/or recurrent tumor. MATERIALS AND METHODS: This retrospective study included patients with native glioblastomas with MR imaging performed at 24-48 hours following resection and 2-4 months postoperatively. 1D and 2D measurements were performed by 2 neuroradiologists with Certificates of Added Qualification. Volumetry was performed by using manual segmentation and computer-assisted volumetry, which combines region-based active contours and a level set approach. Tumor response was assessed by using established 1D, 2D, and volumetric standards. Manual and computer-assisted volumetry segmentation times were compared. Interobserver correlation was determined among 1D, 2D, and volumetric techniques. RESULTS: Twenty-nine patients were analyzed. Discrepancy in disease status between 1D and 2D compared with computer-assisted volumetry was 10.3% (3/29) and 17.2% (5/29), respectively. The mean time for segmentation between manual and computer-assisted volumetry techniques was 9.7 minutes and < 1 minute, respectively (P < .01). Interobserver correlation was highest for volumetric measurements (0.995; 95% CI, 0.990-0.997) compared with 1D (0.826; 95% CI, 0.695-0.904) and 2D (0.905; 95% CI, 0.828-0.948) measurements. CONCLUSIONS: Computer-assisted volumetry provides a reproducible and faster volumetric assessment of enhancing tumor burden, which has implications for monitoring disease progression and quantification of tumor burden in treatment trials.
引用
收藏
页码:498 / 503
页数:6
相关论文
共 30 条
[1]
Abou-Alfa GK, 2012, 24 EORTC NCI AACR S
[2]
[Anonymous], 2906 IR COL U
[3]
[Anonymous], 2013, Patent, Patent No. [PCT/US13/36166, 1336166]
[4]
Dempsey MF, 2005, AM J NEURORADIOL, V26, P770
[5]
GBM Volumetry using the 3D Slicer Medical Image Computing Platform [J].
Egger, Jan ;
Kapur, Tina ;
Fedorov, Andriy ;
Pieper, Steve ;
Miller, James V. ;
Veeraraghavan, Harini ;
Freisleben, Bernd ;
Golby, Alexandra J. ;
Nimsky, Christopher ;
Kikinis, Ron .
SCIENTIFIC REPORTS, 2013, 3
[6]
New response evaluation criteria in solid tumours: Revised RECIST guideline (version 1.1) [J].
Eisenhauer, E. A. ;
Therasse, P. ;
Bogaerts, J. ;
Schwartz, L. H. ;
Sargent, D. ;
Ford, R. ;
Dancey, J. ;
Arbuck, S. ;
Gwyther, S. ;
Mooney, M. ;
Rubinstein, L. ;
Shankar, L. ;
Dodd, L. ;
Kaplan, R. ;
Lacombe, D. ;
Verweij, J. .
EUROPEAN JOURNAL OF CANCER, 2009, 45 (02) :228-247
[7]
Evaluation of early imaging response criteria in glioblastoma multiforme [J].
Gladwish, Adam ;
Koh, Eng-Siew ;
Hoisak, Jeremy ;
Lockwood, Gina ;
Millar, Barbara-Ann ;
Mason, Warren ;
Yu, Eugene ;
Laperriere, Normand J. ;
Menard, Cynthia .
RADIATION ONCOLOGY, 2011, 6
[8]
Brain tumor imaging in clinical trials [J].
Henson, J. W. ;
Ulmer, S. ;
Harris, G. J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (03) :419-424
[9]
Volumetric and MGMT parameters in glioblastoma patients: Survival analysis [J].
Iliadis, Georgios ;
Kotoula, Vassiliki ;
Chatzisotiriou, Athanasios ;
Televantou, Despina ;
Eleftheraki, Anastasia G. ;
Lambaki, Sofia ;
Misailidou, Despina ;
Selviaridis, Panagiotis ;
Fountzilas, George .
BMC CANCER, 2012, 12
[10]
A Novel Method for Volumetric MRI Response Assessment of Enhancing Brain Tumors [J].
Kanaly, Charles W. ;
Ding, Dale ;
Mehta, Ankit I. ;
Waller, Anthony F. ;
Crocker, Ian ;
Desjardins, Annick ;
Reardon, David A. ;
Friedman, Allan H. ;
Bigner, Darell D. ;
Sampson, John H. .
PLOS ONE, 2011, 6 (01)