Hg2+ sensing in aqueous solutions:: an intramolecular charge transfer emission quenching fluorescent chemosensors

被引:57
作者
Cheung, Sin-Man [1 ]
Chan, Wing-Hong [1 ]
机构
[1] Hong Kong Baptist Univ, Dept Chem, Hong Kong, Peoples R China
关键词
chemosensors; mercury probe; dual fluorescence; anthracene;
D O I
10.1016/j.tet.2006.06.035
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
Compounds 4a and 4b, comprising an anthracene moiety as the fluorophore and a pair of dithiocarbamate functionalities as ligating groups, were designed as fluorescent chemosensors for Hg(II). In aqueous solvent systems, upon excitation, in addition to the normal emission bands of locally excited (LE) state of anthracene, both compounds show a prominent pH-independent intramolecular charge transfer (ICT) emissive band, which can be modulated by Hg2+ binding. The systems can be exploited to develop a fluorescent sensitive probe for Hg2+. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:8379 / 8383
页数:5
相关论文
共 17 条
[1]  
*ACS, 1992, ACS S SERIES, V538
[2]  
Beer PD, 2001, ANGEW CHEM INT EDIT, V40, P486, DOI 10.1002/1521-3773(20010202)40:3<486::AID-ANIE486>3.3.CO
[3]  
2-G
[4]  
Brouwer F., 2000, CONFORMATIONAL ANAL, P177
[5]   Development of a mercury ion-selective optical sensor based on fluorescence quenching of 5,10,15,20-tetraphenylporphyrin [J].
Chan, WH ;
Yang, RH ;
Wang, KM .
ANALYTICA CHIMICA ACTA, 2001, 444 (02) :261-269
[6]   Signaling recognition events with fluorescent sensors and switches [J].
de Silva, AP ;
Gunaratne, HQN ;
Gunnlaugsson, T ;
Huxley, AJM ;
McCoy, CP ;
Rademacher, JT ;
Rice, TE .
CHEMICAL REVIEWS, 1997, 97 (05) :1515-1566
[7]   Coupling selectivity with sensitivity in an integrated chemosensor framework:: Design of a Hg2+-responsive probe, operating above 500 nm [J].
Descalzo, AB ;
Martínez-Máñez, R ;
Radeglia, R ;
Rurack, K ;
Soto, J .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (12) :3418-3419
[8]   Cd(II) sensing in water using novel aromatic iminodiacetate based fluorescent chemosensors [J].
Gunnlaugsson, T ;
Lee, TC ;
Parkesh, R .
ORGANIC LETTERS, 2003, 5 (22) :4065-4068
[9]   A highly selective and sensitive fluorescent chemosensor for Hg2+ in neutral buffer aqueous solution [J].
Guo, XF ;
Qian, XH ;
Jia, LH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (08) :2272-2273
[10]   DETERMINATION OF COBALT, COPPER, MERCURY, AND NICKEL AS BIS(2-HYDROXYETHYL)DITHIOCARBAMATE COMPLEXES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KING, JN ;
FRITZ, JS .
ANALYTICAL CHEMISTRY, 1987, 59 (05) :703-708