X-ray focusing test and x-ray imaging test by a microcapillary x-ray lens at an undulator beamline

被引:45
作者
Kohmura, Y
Awaji, M
Suzuki, Y
Ishikawa, T
Dudchik, YI
Kolchevsky, NN
Komarov, FF
机构
[1] Inst Phys & Chem Res, Harima Inst, SPring 8, Mikazuki, Hyogo 6795148, Japan
[2] Japan Synchrotron Radiat Res Inst, SPring 8, Mikazuki, Hyogo 6795198, Japan
[3] Inst Appl Phys Problems, Minsk 220064, BELARUS
关键词
D O I
10.1063/1.1150045
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A first focusing test of the undulator radiation at SPring-8 has been done using two types of x-ray refractive lenses in thin glass capillaries. One (lens No. 1) contained bubbles in a glue whereas the other (lens No. 2) contained bubbles in glycerol. The capillaries had inner diameters of 0.2 and 0.8 mm, respectively. Using x rays of 17-18 keV, the undulator source image was investigated at the focal plane. The spherical aberrations and the field distortions were carefully examined by taking the images of a gold mesh. Lens No. 1 had an advantage of high transmissivity in the hard x-ray region (18% at 18 keV) and high tolerance to severe radiation damage, e.g., similar to 5 x 10(12) photons/s/0.03 mm(2) of the 18 keV x rays for an exposure time of 1 h. On the other hand, lens No. 2 had an advantage of a large aperture, 0.8 mm, and a small field distortion, e.g., less than 10% inside a diameter of 300 mu m. (C) 1999 American Institute of Physics. [S0034-6748(99)05011-X].
引用
收藏
页码:4161 / 4167
页数:7
相关论文
共 16 条
[1]   Beryllium and aluminium refractive collimators for synchrotron radiation [J].
Baron, AQR ;
Kohmura, Y ;
Krishnamurthy, VV ;
Shvyd'ko, YV ;
Ishikawa, T .
JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 :953-956
[2]   A refractive collimator for synchrotron radiation [J].
Baron, AQR ;
Kohmura, Y ;
Ohishi, Y ;
Ishikawa, T .
APPLIED PHYSICS LETTERS, 1999, 74 (10) :1492-1494
[3]   A microcapillary lens for X-rays [J].
Dudchik, YI ;
Kolchevsky, NN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 421 (1-2) :361-364
[4]   Two-plane focusing of 30 keV undulator radiation [J].
Elleaume, P .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :1-5
[5]   In-vacuum undulators of SPring-8 [J].
Hara, T ;
Tanaka, T ;
Tanabe, T ;
Marechal, XM ;
Okada, S ;
Kitamura, H .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :403-405
[6]   Present status of SPring-8 insertion devices [J].
Kitamura, H .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :184-188
[7]   X-ray bubble lens and X-ray hollow plastic ball lens [J].
Kohmura, Y ;
Awaji, M ;
Suzuki, Y ;
Ishikawa, T .
X-RAY MICROFOCUSING: APPLICATIONS AND TECHNIQUES, 1998, 3449 :185-194
[8]  
KOHMURA Y, 1998, SPRING 8 USER INFORM, V3, P28
[9]   Transmission and gain of singly and doubly focusing refractive x-ray lenses [J].
Lengeler, B ;
Tummler, J ;
Snigirev, A ;
Snigireva, I ;
Raven, C .
JOURNAL OF APPLIED PHYSICS, 1998, 84 (11) :5855-5861
[10]  
MOCHIZUKI T, UNPUB