Light at the end of the tunnel: recent analytical applications of liquid-core waveguides

被引:103
作者
Dallas, T [1 ]
Dasgupta, PK [1 ]
机构
[1] Texas Tech Univ, Lubbock, TX 79409 USA
关键词
D O I
10.1016/S0165-9936(04)00504-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Optical chemical analysis systems are the most important tools to analytical chemists in need of sensitive measurement techniques. Liquid-core waveguides (Fig. 1) have proved to be an important innovation that has led to improvements in detection limits when incorporated into many types of optical analysis systems, especially UV-Vis absorbance, fluorescence and Raman measurements. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:385 / 392
页数:8
相关论文
共 75 条
[1]   Low-loss liquid-core optical fiber for low-refractive-index liquids: fabrication, characterization, and application in Raman spectroscopy [J].
Altkorn, R ;
Koev, I ;
VanDuyne, RP ;
Litorja, M .
APPLIED OPTICS, 1997, 36 (34) :8992-8998
[2]   Intensity considerations in liquid core optical fiber Raman spectroscopy [J].
Altkorn, R ;
Malinsky, MD ;
Van Duyne, RP ;
Koev, I .
APPLIED SPECTROSCOPY, 2001, 55 (04) :373-381
[3]   Raman performance characteristics of Teflon®-AF 2400 liquid-core optical-fiber sample cells [J].
Altkorn, R ;
Koev, I ;
Pelletier, MJ .
APPLIED SPECTROSCOPY, 1999, 53 (10) :1169-1176
[4]   Liquid core waveguide with fiber optic coupling for remote pollution monitoring in the deep ultraviolet [J].
Belz, M ;
Dress, P ;
Klein, KF ;
Boyle, WJO ;
Franke, H ;
Grattan, KTV .
WATER SCIENCE AND TECHNOLOGY, 1998, 37 (12) :279-284
[5]   Linearity and effective optical pathlength of liquid waveguide capillary cells. [J].
Belz, M ;
Dress, P ;
Sukhitskiy, A ;
Liu, S .
INTERNAL STANDARDIZATION AND CALIBRATION ARCHITECTURES FOR CHEMICAL SENSORS, 1999, 3856 :271-281
[6]  
BELZ M, 2002, J ROERAADE ELECTROPH, V23, P1467
[7]   Spectrophotometric measurement of total inorganic carbon in aqueous solutions using a liquid core waveguide [J].
Byrne, RH ;
Liu, XW ;
Kaltenbacher, EA ;
Sell, K .
ANALYTICA CHIMICA ACTA, 2002, 451 (02) :221-229
[8]   Use of liquid core waveguides for long pathlength absorbance spectroscopy: Principles and practice - Comment [J].
Byrne, RH ;
Kaltenbacher, E .
LIMNOLOGY AND OCEANOGRAPHY, 2001, 46 (03) :740-742
[9]   Construction of a compact spectrofluorometer/spectrophotometer system using a flexible liquid core waveguide [J].
Byrne, RH ;
Yao, WS ;
Kaltenbacher, E ;
Waterbury, RD .
TALANTA, 2000, 50 (06) :1307-1312
[10]   Long pathlength absorbance spectroscopy: trace copper analysis using a 4.4 m liquid core waveguide [J].
Callahan, MR ;
Rose, JB ;
Byrne, RH .
TALANTA, 2002, 58 (05) :891-898