Effects of separation length and voltage on isolectric focusing in a plastic microfluidic device

被引:43
作者
Das, Champak
Fan, Z. Hugh
机构
[1] Univ Florida, Dept Mech & Aerosp Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Biomed Engn, Gainesville, FL 32611 USA
关键词
IEF; microfluidics; pH gradient compression; whole-channel imaging;
D O I
10.1002/elps.200600013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes the investigation on the effects of separation length and voltage on IEF in a plastic microfluidic device. A LIF, whole-channel imaging detection (WCID) system was developed to monitor proteins while they were moving under an electric field. IEF was carried out in a separation medium consisting of carrier ampholytes and a mixture of linear polymers (hydroxyethylcellulose and hydroxypropylcellulose). We found that the IEF separation resolution is essentially independent of separation length when the same voltage is applied, which agrees with the theory. This result supports the notion that IEF in a microfabricated device leads to more rapid analysis without sacrificing the resolving power. A higher separation voltage also brought about more rapid analysis and superior separation resolution. IEF of two proteins (green fluorescence protein and R-phycoerythrin) was achieved in 1.5 min when 500 V was applied across a 1.9-cm channel. We found that a linear relationship exists between the focusing time and the inverse of the electrical field strength. In addition, we confirmed the phenomenon in which the pH gradient was compressed to the middle of a channel, and we found that the relative amount of the gradient compression decreased with the channel length.
引用
收藏
页码:3619 / 3626
页数:8
相关论文
共 43 条
[1]  
Anderson R.L., 1987, Practical Statistics for Analytical Chemists
[2]  
Baker D. R., 1995, CAPILLARY ELECTROPHO
[3]  
BIDLINGMEYER BA, 1984, ANAL CHEM, V56, P1583
[4]   Plastic advances microfluidic devices. [J].
Boone, T ;
Fan, ZH ;
Hooper, H ;
Ricco, A ;
Tan, HD ;
Williams, S .
ANALYTICAL CHEMISTRY, 2002, 74 (03) :78A-86A
[5]   A prototype two-dimensional capillary electrophoresis system fabricated in poly(dimethylsiloxane) [J].
Chen, XX ;
Wu, HK ;
Mao, CD ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2002, 74 (08) :1772-1778
[6]   Isoelectric focusing in a poly(dimethylsiloxane) microfluidic chip [J].
Cui, HC ;
Horiuchi, K ;
Dutta, P ;
Ivory, CF .
ANALYTICAL CHEMISTRY, 2005, 77 (05) :1303-1309
[7]   A laser-induced fluorescence imaging system for isoelectric focusing [J].
Das, C ;
Xia, Z ;
Stoyanov, A ;
Fan, ZH .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 2005, 33 (04) :379-389
[8]  
DAS C, 2004, LASER INDUCED FLUORE, V5591
[9]   MICROMACHINING OF CAPILLARY ELECTROPHORESIS INJECTORS AND SEPARATORS ON GLASS CHIPS AND EVALUATION OF FLOW AT CAPILLARY INTERSECTIONS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :177-184
[10]   Cross-linked polyacrylarnide coating for capillary isoelectric focusing [J].
Gao, L ;
Liu, SR .
ANALYTICAL CHEMISTRY, 2004, 76 (24) :7179-7186