Clinical assessment of high-strength all-ceramic crowns

被引:130
作者
Haselton, DR [1 ]
Diaz-Arnold, AM [1 ]
Hillis, SL [1 ]
机构
[1] Univ Iowa, Coll Dent, Dept Family Dent, Iowa City, IA 52242 USA
关键词
D O I
10.1016/S0022-3913(00)70033-3
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Statement of problem, All-ceramic crowns are being used extensively. Little data are available on their clinical performance. Purpose, This study evaluated thr: clinical performance of In-Ceram (Vita Zahnfabrik) crowns. Material and methods. Forty-one patients (16 men, 25 nomen; mean age 47.3 years, range 18 to 77 years) were examined with a total of SO In-Ceram all-ceramic crowns fabricated at the University of Iowa College of Dentistry from 1994 to 1997. The percentage distribution for crowns included: 67% anterior single crowns, 26% posterior single crowns, 6% anterior implant crowns, and 1% posterior implant crowns. This study documented the integrity of the junction between crown and tooth, color match to adjacent teeth, secondary dental caries, wear of crown and opposing dentition, and visible cracks in the crown. Alpha, Bravo, and Charlie ratings were assigned with a modified USPHS criteria. The patients were also surveyed with respect to oral hygiene and satisfaction of treatment. Estimations of 4-year success rates and corresponding confidence intervals were calculated by fitting a. constant hazard function model with the SAS procedures GENMOD. Results, Marginal integrity for 88% of artificial crowns was rated,Alpha or Bravo. Shade match fur 99% nas Bravo or better. Only 1% of the crowns were carious, and 1 crown exhibited occlusal wear. One premolar crown had a small fracture of veneering porcelain. One molar crown was remade after core fracture. All patients (100%) expressed satisfaction with their crowns. The estimated 4-year success rates (Alpha or Bravo), with 95% confidence intervals in parentheses were calculated as: 83.5% (65.7%-94.6%) for marginal integrity, 95.8% (82.9%-99.8%) fur shade match, and 95.5% (81.6%-99.7%) for secondary caries, 100% (88%-100%) for wear and 100% (88%-100%) for cracks.
引用
收藏
页码:396 / 401
页数:6
相关论文
共 31 条
[1]
Anusavice K J, 1992, Adv Dent Res, V6, P82
[2]
TISSUE RESPONSE TO FIXED PARTIAL DENTURE PONTICS [J].
CAVAZOS, E .
JOURNAL OF PROSTHETIC DENTISTRY, 1968, 20 (02) :143-&
[3]
PLAQUE RETENTION ON TEETH RESTORED WITH FULL-CERAMIC CROWNS - A COMPARATIVE-STUDY [J].
CHAN, C ;
WEBER, H .
JOURNAL OF PROSTHETIC DENTISTRY, 1986, 56 (06) :666-671
[4]
Collet D., 1994, MODELLING SURVIVAL D, V1st
[5]
COX DR, 1983, ANAL SURVIVAL DATA, P36
[6]
Fahrmeir L., 1994, MULTIVARIATE STAT MO, DOI 10.1007/978-1-4899-0010-4
[7]
Longitudinal study of pressed glass-ceramic inlays for four and a half years [J].
Fradeani, M ;
Aquilano, A ;
Bassein, L .
JOURNAL OF PROSTHETIC DENTISTRY, 1997, 78 (04) :346-353
[8]
FLEXURAL STRENGTH OF AN INFUSED CERAMIC, GLASS-CERAMIC, AND FELDSPATHIC PORCELAIN [J].
GIORDANO, RA ;
PELLETIER, L ;
CAMPBELL, S ;
POBER, R .
JOURNAL OF PROSTHETIC DENTISTRY, 1995, 73 (05) :411-418
[9]
A COMPRESSIVE STRENGTH STUDY OF COMPLETE CERAMIC CROWNS .2. [J].
JOSEPHSON, BA ;
SCHULMAN, A ;
DUNN, ZA ;
HURWITZ, W .
JOURNAL OF PROSTHETIC DENTISTRY, 1991, 65 (03) :388-391
[10]
Kelly J R, 1990, Int J Prosthodont, V3, P430