Comparison of different sample preparation techniques in TEM observation of microstructure of INCONEL alloy 783 subjected to prolonged isothermal exposure

被引:22
作者
Ma, LZ [1 ]
机构
[1] Univ Nevada, Harry Reid Ctr Environm Studies, Las Vegas, NV 89154 USA
关键词
alloy; 783; jet electro-polishing; ion milling; focused ion beam (FIB);
D O I
10.1016/j.micron.2003.10.048
中图分类号
TH742 [显微镜];
学科分类号
摘要
INCONEL alloy 783 was annealed and aged following the standard heat treatment procedure. One set of specimens was then isothermally exposed at 500 degreesC for 3000 h. Mechanical properties were measured at room temperature and 650 degreesC, and the results showed the prolonged exposure increased the strength and decreased elongation of alloy 783. The microstructures of as-produced and exposed material were examined using optical microscope, SEM and TEM, respectively. Three techniques, jet electro-polishing, ion milling, and focused ion beam, were employed to prepare the TEM samples to observe the variation of microstructure of alloy 783 due to isothermal exposure. TEM images of samples prepared by different methods were analyzed and compared. The results indicate that the jet electro-polishing technique allows the detail microstructure of alloy 783 subjected to different treatments to be well revealed, and thereby the TEM images can be used to explain the enhancement of strength of alloy 783 caused by isothermal exposure. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:273 / 279
页数:7
相关论文
共 8 条
[1]  
Ma L. Z., 2000, P 9 INT S SUP TMS 7, P601
[2]   Effect of prolonged isothermal exposure on elevated-temperature, time-dependent fatigue-crack propagation in INCONEL alloy 783 [J].
Ma, LZ ;
Chang, KM ;
Mannan, SK ;
Patel, SJ .
METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2002, 33 (11) :3465-3478
[3]  
Ma LZ, 2000, ADVANCED TECHNOLOGIES FOR SUPERALLOY AFFORDABILITY, P131
[4]  
Mannan S., 1998, INT GAS TURB AER C E, P1
[5]   Applications of focused ion beam microscopy to materials science specimens [J].
Phaneuf, MW .
MICRON, 1999, 30 (03) :277-288
[6]  
SMITH JS, 1996, P 8 INT S SUP 7 SPRI, P91
[7]  
WILLIAMS DB, 1996, TRANSMISSION ELECT M, V1
[8]  
Young RR, 1998, PRINCIPLES OF NEUROLOGIC REHABILITATION, P329