Analytical algorithm for the generation of polygonal projection data for tomographic reconstruction

被引:5
作者
Davis, GR
机构
[1] Dept. of Biophys. in Rel. to Dent., Faculty of Dentistry, Queen Mary and Westfield College, London E1 2AD, Turner Street
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1016/S0168-9002(96)00829-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Tomographic reconstruction algorithms and filters can be tested using a mathematical phantom, that is, a computer program which takes numerical data as its input and outputs derived projection data. The input data is usually in the form of pixel ''densities'' over a regular grid, or position and dimensions of simple, geometrical objects. The former technique allows a greater variety of objects to be simulated, but is less suitable in the case when very small (relative to the ray-spacing) features are to be simulated. The second technique is normally used to simulate biological specimens, typically a human skull, modelled as a number of ellipses. This is not suitable for simulating non-biological specimens with features such as straight edges and fine cracks. We have therefore devised an algorithm for simulating objects described as a series of polygons. These polygons, or parts of them, may be smaller than the ray-spacing and there is no limit, except that imposed by computing resources, on the complexity, number or superposition of polygons. A simple test of such a phantom, reconstructed using the filtered back-projection method, revealed reconstruction artefacts not normally seen with ''biological'' phantoms.
引用
收藏
页码:548 / 552
页数:5
相关论文
共 8 条
[1]  
GUVENILIR A, 1994, P 4 INT C AL ALL THE, V2, P413
[2]  
Joseph P M, 1982, IEEE Trans Med Imaging, V1, P192, DOI 10.1109/TMI.1982.4307572
[3]   SUBPIXEL RESOLUTION IN 3D CONE-BEAM MICROTOMOGRAPHY [J].
LIKHACHOV, AV ;
PICKALOV, VV .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 359 (1-2) :370-375
[4]   3-DIMENSIONAL RECONSTRUCTION FROM RADIOGRAPHS AND ELECTRON MICROGRAPHS - APPLICATION OF CONVOLUTIONS INSTEAD OF FOURIER TRANSFORMS [J].
RAMACHANDRAN, GN ;
LAKSHMINARAYANAN, AV .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1971, 68 (09) :2236-+
[5]  
Rosenfeld A., 1982, Digital Picture Processing, V1/2
[6]   FOURIER RECONSTRUCTION OF A HEAD SECTION [J].
SHEPP, LA ;
LOGAN, BF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (03) :21-43
[7]   STUDY OF REPROJECTION METHODS IN TERMS OF THEIR RESOLUTION LOSS AND SAMPLING ERRORS [J].
YU, DC ;
HUANG, SC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1174-1178
[8]   NUMERICAL EVALUATION OF METHODS FOR COMPUTING TOMOGRAPHIC PROJECTIONS [J].
ZHUANG, W ;
GOPAL, SS ;
HEBERT, TJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1660-1665