A novel mechatronic body weight support system

被引:144
作者
Frey, Martin
Colombo, Gery
Vaglio, Martino
Bucher, Rainer
Joerg, Matthias
Riener, Robert
机构
[1] Swiss Fed Inst Technol, CH-8092 Zurich, Switzerland
[2] Balgrist Univ Technol, CH-8008 Zurich, Switzerland
[3] Hocoma AG, CH-8604 Volketswil, Switzerland
关键词
dynamic body weight support (BWS); force control; ground reaction force; rehabilitation of neurological impairments; rehabilitation robotics; treadmill training;
D O I
10.1109/TNSRE.2006.881556
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
A novel mechatronic body weight support (BWS) system has been developed to provide precise body weight unloading for patients with neurological or other impairments during treadmill training. The system is composed of a passive elastic spring element to take over the main unloading, force and an active closed-loop controlled electric drive to generate the exact desired force. Both force generating units, the passive spring and the active electric drive, act on the patient via a polyester rope connected to a harness worn by the patient. The length of the rope can be adjusted with an electric winch to adapt the system to different patient sizes. The system is fully computer controlled. At unloading loads of up to 60 kg and walking speeds of up to 3.2 km/h, the mean unloading error and the maximum unloading error of the presented. BWS system was less than 1 and 3 kg, respectively. The performance was compared with those of two purely passive BWS systems currently being used by most other rehabilitation groups. This comprised counterweight systems and static BWS systems with fixed rope lengths. Counterweight systems reached mean and maximum unloading errors of up to 5.34 and 16.22 kg, respectively. The values for the static BWS were 11.02 kg and 27.67 kg, respectively. The novel mechatronic BWS system presented in this study adjusts desired unloading changes of up to 20 kg within less than 100 ms. Thus, not only constant BWS, but also gait cycle dependent or time variant oscillations of the desired force can be realized with high accuracy. Precise and constant unloading force is believed to be an important prerequisite for BWS gait therapy, where it is important to generate physiologically correct segmental dynamics and ground reaction forces. Thus, the novel BWS system presented in this paper is an important contribution to maximize the therapeutic outcome of human gait rehabilitation.
引用
收藏
页码:311 / 321
页数:11
相关论文
共 20 条
[1]
Adams R. J., 1998, Proceedings of the ASME Dynamic Systems and Control Division-1998, P227
[2]
DESCRIPTION AND APPLICATION OF A SYSTEM FOR LOCOMOTOR REHABILITATION [J].
BARBEAU, H ;
WAINBERG, M ;
FINCH, L .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1987, 25 (03) :341-344
[3]
MECHANICAL WORK IN TERRESTRIAL LOCOMOTION - 2 BASIC MECHANISMS FOR MINIMIZING ENERGY-EXPENDITURE [J].
CAVAGNA, GA ;
HEGLUND, NC ;
TAYLOR, CR .
AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 233 (05) :R243-R261
[4]
CHEN G, 2001, 6 ANN GAIT CLIN MOV
[5]
Colombo G, 2000, J REHABIL RES DEV, V37, P693
[6]
COOK G, 2002, Patent No. 20020065173
[7]
Locomotor activity in spinal man:: significance of afferent input from joint and load receptors [J].
Dietz, V ;
Müller, R ;
Colombo, G .
BRAIN, 2002, 125 :2626-2634
[8]
FREY M, IN PRESS PRESENCE
[9]
WARD: A pneumatic system for body weight relief in gait rehabilitation [J].
Gazzani, F ;
Fadda, A ;
Torre, M ;
Macellari, V .
IEEE TRANSACTIONS ON REHABILITATION ENGINEERING, 2000, 8 (04) :506-513
[10]
GORDON KE, 2003, Patent No. 03035184