Optimization of apertures and collimators for multi-channel plasma diagnostics

被引:12
作者
Ingesson, LC
Wilson, DJ
机构
[1] EURATOM, FOM Inst Plasmafys Rijnhuizen, Trilateral Euregio Cluster, NL-3430 BE Nieuwegein, Netherlands
[2] UKAEA Euratom Fus Assoc, Culham Sci Ctr, Abingdon OX14 3DB, Oxon, England
关键词
D O I
10.1063/1.1491031
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Aperture, pin-hole and collimator detection systems are often used in plasma diagnostics, for example, in soft x-ray detection and bolometer systems. In this article the simultaneous optimization of viewing-beam overlap and light yield is considered in multi-channel aperture and collimator systems for two-dimensional (2D) tomography. This article briefly highlights the relation between beamwidth overlap and spatial aliasing in tomography, and how aliasing can be avoided in theory and in practice. Three-dimensional (3D) single-channel aperture and collimator systems can be approximated by a combination of two planar systems if the aperture is rectangular. Three ways to optimize beamwidth overlap and light yield for planar aperture and collimator systems are considered in detail: overlap of the angular etendue at the full width at half maximum (FWHM), overlap of the geometric function at the FWHM a certain distance from the aperture, and arbitrary overlap for a given maximum beamwidth. The combination of 2D effects from all three optimization methods were used in the design of 3D apertures for a new multi-channel bolometer camera on the Joint European Torus tokamak. The resulting apertures are complex, but the new camera has several advantages over previous cameras. (C) 2002 American Institute of Physics.
引用
收藏
页码:2890 / 2899
页数:10
相关论文
共 15 条
[1]  
BECK RN, 1985, IEEE T NUCL SCI, V32, P875
[2]   CORRECTION FOR COLLIMATOR WIDTH (RESTORATION) IN RECONSTRUCTIVE X-RAY TOMOGRAPHY [J].
BRACEWELL, RN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (01) :6-15
[3]   SOFT-X-RAY TOMOGRAPHY DIAGNOSTIC AT THE RTP TOKAMAK [J].
DACRUZ, DF ;
DONNE, AHJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (07) :2295-2305
[4]   Geometrical response of multihole collimators [J].
Formiconi, AR .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (11) :3359-3379
[5]   Fast bolometric measurements on the TCV tokamak [J].
Furno, I ;
Weisen, H ;
Mlynar, J ;
Pitts, RA ;
Llobet, X ;
Marmillod, P ;
Pochon, GP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (12) :4552-4556
[6]  
Ingesson L.C., 1999, JETR9906 JET JOINT U
[7]   Characterization of geometrical detection-system properties for two-dimensional tomography [J].
Ingesson, LC ;
Maggi, CF ;
Reichle, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03) :1370-1378
[8]   Projection-space methods to take into account finite beam width effects in two-dimensional tomography algorithms [J].
Ingesson, LC ;
Böcker, PJ ;
Reichle, R ;
Romanelli, M ;
Smeulders, P .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (01) :17-27
[9]   2D TOMOGRAPHY WITH BOLOMETRY IN DIII-D [J].
LEONARD, AW ;
MEYER, WH ;
GEER, B ;
BEHNE, DM ;
HILL, DN .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1201-1204
[10]  
LINDGREN AG, 1981, ADV ELECTRON EL PHYS, V56, P359