The influence of PEEP and tidal volume on central blood volume

被引:16
作者
Kubitz, J. C.
Kemming, G. I.
Schultheiss, G.
Starke, J.
Podtschaske, A.
Goetz, A. E.
Reuter, D. A.
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Anaesthesiol, Med Ctr, D-20246 Hamburg, Germany
[2] Univ Munich, Munich, Germany
[3] Univ Munich, Klinikum Grosshadern, Dept Anaesthesiol, D-8000 Munich, Germany
[4] Inst Surg Res, Munich, Germany
关键词
ventricular function; blood volume; continuous positive airway pressure; cardiac volume; end-diastolic volume; tidal volume;
D O I
10.1017/S0265021506000925
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective: Measurement of central blood volumes (CBV), such as global end-diastolic volume (GEDV) and right ventricular end-diastolic volume (RVEDV) are considered appropriate estimates of intravascular volume status. However, to apply those parameters for preload assessment in mechanically ventilated patients, the influence of tidal volume (TV) and positive endexpiratory airway pressure (PEEP) on those parameters must be known. Methods: In 13 mechanically ventilated piglets, the effect of low (10 mL kg(-1)) and high (20 mL kg(-1)) TVs on CBV was investigated in absence and presence of PEEP (0 and 15 cmH(2)O). GEDV, RVEDV, right heart (RHEDV) and left heart end-diastolic volume (LHEDV) were measured by thermodilution. Blood flow on the descending thoracic aorta measured with an ultrasonic flow-probe served to determine stroke volume (SW Measurements were performed during baseline conditions, after volume loading with previously extracted haemodilution blood (20 mL kg(-1)) and following haemorrhage (30 mL kg I). Results: Application of PEEP decreased GEDV and SV significantly (P < 0.05). Augmenting TV did not reduce GEDV systematically, but significantly reduced SV (P < 0.05). Changes in ventilator settings only influenced RVEDV following volume loading (P < 0.05). RHEDV and LHEDV decreased following application of PEEP, but only RHEDV decreased after augmenting TV at baseline and following volume loading. Correlation of SV with parameters of CBV was r = 0.487 (P < 0.01) for GEDV r = 0.553 (P < 0.01) for RVEDV, r = 0.596 (P < 0.01) for RHEDV and r = 0.303 (P < 0.01) for LHEDV Conclusion: Application of PEEP decreases CBV and SV. Augmenting TV reduces SV but not CBV There is a moderate correlation between parameters of CBV and cardiac performance.
引用
收藏
页码:954 / 961
页数:8
相关论文
共 24 条
[1]   Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care [J].
Bendjelid, K ;
Romand, JA .
INTENSIVE CARE MEDICINE, 2003, 29 (03) :352-360
[2]  
BIONDI JW, 1988, ANESTH ANALG, V67, P144
[3]   Right ventricular end-diastolic volume index as a predictor of preload status in patients on positive end-expiratory pressure [J].
Cheatham, ML ;
Nelson, LD ;
Chang, MC ;
Safcsak, K .
CRITICAL CARE MEDICINE, 1998, 26 (11) :1801-1806
[4]   Preload index: Pulmonary artery occlusion pressure versus intrathoracic blood volume monitoring during lung transplantation [J].
Della Rocca, G ;
Costa, GM ;
Coccia, C ;
Pompei, L ;
Di Marco, P ;
Pietropaoli, P .
ANESTHESIA AND ANALGESIA, 2002, 95 (04) :835-843
[5]  
DIEBEL LN, 1992, ARCH SURG-CHICAGO, V127, P817
[6]   Effects of increasing airway pressure and PEEP on the assessment of cardiac preload [J].
Diebel, LN ;
Myers, T ;
Dulchavsky, S .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1997, 42 (04) :585-591
[7]   BEDSIDE ASSESSMENT OF INTRAVASCULAR VOLUME STATUS IN PATIENTS UNDERGOING CORONARY-BYPASS SURGERY [J].
HOEFT, A ;
SCHORN, B ;
WEYLAND, A ;
SCHOLZ, M ;
BUHRE, W ;
STEPANEK, E ;
ALLEN, SJ ;
SONNTAG, H .
ANESTHESIOLOGY, 1994, 81 (01) :76-86
[8]   INFLUENCE OF POSITIVE END-EXPIRATORY PRESSURE ON RIGHT AND LEFT-VENTRICULAR PERFORMANCE ASSESSED BY DOPPLER 2-DIMENSIONAL ECHOCARDIOGRAPHY [J].
HUEMER, G ;
KOLEV, N ;
KURZ, A ;
ZIMPFER, M .
CHEST, 1994, 106 (01) :67-73
[9]   REEVALUATION OF HEMODYNAMIC CONSEQUENCES OF POSITIVE PRESSURE VENTILATION - EMPHASIS ON CYCLIC RIGHT VENTRICULAR AFTERLOADING BY MECHANICAL LUNG-INFLATION [J].
JARDIN, F ;
DELORME, G ;
HARDY, A ;
AUVERT, B ;
BEAUCHET, A ;
BOURDARIAS, JP .
ANESTHESIOLOGY, 1990, 72 (06) :966-970
[10]   INTRATHORACIC BLOOD-VOLUME ACCURATELY REFLECTS CIRCULATORY VOLUME STATUS IN CRITICALLY ILL PATIENTS WITH MECHANICAL VENTILATION [J].
LICHTWARCKASCHOFF, M ;
ZERAVIK, J ;
PFEIFFER, UJ .
INTENSIVE CARE MEDICINE, 1992, 18 (03) :142-147