Modelling, analysis, and irreversibility reduction of the triple-pressure reheat H-system combined cycle

被引:6
作者
Bassily, A. M. [1 ]
机构
[1] Frederick Inst Technol, Dept Engn Mech, CY-1036 Nicosia, Cyprus
关键词
gas-steam combined cycle; gas turbine combined cycle; improving efficiency; reduced irreversibility; steam generator; the heat recovery steam generator; steam cooled; steam-air cooled;
D O I
10.1243/09576509JPE281
中图分类号
O414.1 [热力学];
学科分类号
摘要
The triple-pressure reheat H-system combined cycle is considered the most efficient combined cycle that is commercially available. The gas turbine of the H-system combined cycle is cooled using a closed loop of steam and an open loop of air. Compared with the regular triple-pressure reheat combined cycle, the heat recovery steam generator (HRSG) of the H-system has a different configuration and a reduced load since superheating of steam is partially performed by the gas turbine. In this paper, the triple-pressure reheat H-system combined cycle was modelled, including detailed modelling of the HRSG and the expansion and cooling processes of the gas turbine. The performance of the H-system combined cycle was analysed and a feasible technique to reduce the irreversibility of the HRSG was introduced. The reduced- irreversibility triple-pressure reheat steam-air gas turbine-cooled (H-system) combined cycle(dagger) was compared with the regularly designed triple-pressure reheat H-system combined cycle, which is the typical design for a commercial combined cycle. The effects of varying the turbine inlet temperature (TIT) on the performance of all cycles were presented and discussed. The results indicate that the reduced-irreversibility H-system combined cycle is 1.45-1.65 per cent higher in efficiency and 2.5 per cent higher in the total specific work than the regularly designed H-system combined cycle when all compared at the same values of TIT and minimum temperature difference for pinch points (PPm). The reduced-irreversibility H-system combined cycle was 1.35 per cent higher in efficiency than the most efficient commercially available H-system combined cycle when compared at the same value of TIT. Economical analysis of the reduced-irreversibility cycle was performed and showed that applying the introduced technique could result in an annual saving of ten million US dollars for a 440 MW power plant.
引用
收藏
页码:883 / 898
页数:16
相关论文
共 23 条
[1]   Modeling, numerical optimization, and irreversibility reduction of a dual-pressure reheat combined-cycle [J].
Bassily, AM .
APPLIED ENERGY, 2005, 81 (02) :127-151
[2]   Modelling and numerical optimization of dual- and triple-pressure combined cycles [J].
Bassily, AM .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2004, 218 (A2) :97-109
[3]   Effects of evaporative inlet and aftercooling on the recuperated gas turbine cycle [J].
Bassily, AM .
APPLIED THERMAL ENGINEERING, 2001, 21 (18) :1875-1890
[4]  
BASSILY AM, 2006, ENERGY 206
[5]   Thermoeconomic optimization of heat recovery steam generators operating parameters for combined plants [J].
Casarosa, C ;
Donatini, F ;
Franco, A .
ENERGY, 2004, 29 (03) :389-414
[6]   A thermodynamic analysis of different options to break 60% electric efficiency in combined cycle power plants [J].
Chiesa, P ;
Macchi, E .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2004, 126 (04) :770-785
[7]  
Cohen H., 1996, GAS TURBINE THEORY, p[50, 222, 340]
[8]  
Davis L.B., 2000, GER3568G
[9]  
Dick E., 1997, EUR J MECH ENG, V42, P67
[10]  
*GE POW SYST, 2003, POWER, V147, P45