Investigation into the origin of the noise of surface electrodes

被引:269
作者
Huigen, E [1 ]
Peper, A [1 ]
Grimbergen, CA [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Phys Med, NL-1105 AZ Amsterdam, Netherlands
关键词
electrodes; electrode noise; biopotential recordings; Ag-AgCl electrolyte-skin interface; metal-electrolyte interface;
D O I
10.1007/BF02344216
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In the recording of biomedical signals, a significant noise component is introduced by the electrode. The magnitude of this noise is considerably higher than the equivalent thermal noise from the electrode impedance. As the noise in surface electrodes limits the resolution of biopotential recordings, it is important to understand its origin. It was found that the noise mainly originates in the electrolyte-skin interface and that it is highly dependent on the electrode gel used and the skin properties of the test subject. Depending on skin treatment, magnitudes between 1 and 20 muV(rms) were measured among subjects. When the metal-electrolyte interface was allowed time to stabilise, electrodes of different metals measured face to face all showed a negligibly small noise magnitude (< 1 muV(rms)), In pre-gelled electrodes, where the metal-electrolyte interface has stabilised, no difference in noise properties was found between Ag-AgCl electrodes and other metals when measured on the skin. In subjects at rest, the contribution of EMG signals to the total noise level was shown to be negligibly small compared with the noise contribution of the electrolyte-skin interface. The magnitude of the noise of electrodes appeared to be inversely proportional to the square root of the area of the electrode on the skin.
引用
收藏
页码:332 / 338
页数:7
相关论文
共 19 条
[1]  
[Anonymous], 1975, PRINCIPLES APPL BIOM
[2]  
CARIM HM, 1988, ENCY MED DEVICES INS, P195
[3]  
EGGINS BR, 1993, ANALIST, V188, P439
[4]  
Fernandez Mireya, 2000, Biomedical Instrumentation and Technology, V34, P125
[5]  
FLASTERSTEIN A. H., 1966, MED BIOL ENG, V4, P583, DOI 10.1007/BF02474828
[6]  
Geddes LA, 1972, ELECTRODES MEASUREME
[7]   NOISE CHARACTERISTICS OF STAINLESS-STEEL SURFACE ELECTRODES [J].
GODIN, DT ;
PARKER, PA ;
SCOTT, RN .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (06) :585-590
[8]  
GONDRAN C, 1995, INNOV TECH BIOL MED, V16, P113
[9]   Noise of surface bio-potential electrodes based on NASICON ceramic and Ag-AgCl [J].
Gondran, C ;
Siebert, E ;
Yacoub, S ;
Novakov, E .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (06) :460-466
[10]  
GRIMBERGEN CA, 1993, P 14 ANN INT C IEEE, V14, P2382