Use of focused ion beam milling for investigating the mechanical properties of biological tissues: A study of human primary molars

被引:45
作者
Chan, Y. L. [1 ]
Ngan, A. H. W. [1 ]
King, N. M.
机构
[1] Univ Hong Kong, Dept Mech Engn, Pokfulam Rd, Hong Kong, Hong Kong, Peoples R China
关键词
ULTIMATE TENSILE-STRENGTH; ELASTIC-MODULUS; SENSING INDENTATION; FRACTURE-TOUGHNESS; PRISM ORIENTATION; ENAMEL; NANOINDENTATION; DENTIN; THICKNESS; BEHAVIOR;
D O I
10.1016/j.jmbbm.2009.01.006
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
In this paper, the usefulness of the specimen shaping ability of focused ion beam (FIB) milling in the micrometer scale and the high force resolution of the nanoindentation technique are demonstrated on human primary teeth. Micro-cantilevers, with a triangular cross-section < 5 mu m in width and 10 mu m in length, were produced within 50 mu m of the dentin-enamel junction (DEJ) using FIB milling, and were point-loaded at their free ends at 20 mu N/s until failure using a nanoindenter. The elastic modulus and flexural strength of such micro-samples of human enamel, and their variation with respect to prism orientation, were studied and compared to data from bulk enamel measured using nanoindentation and three-point bend tests. The elastic modulus of the micro-cantilever samples was found to be comparable to that obtained by nanoindentation on bulk samples, but it demonstrated significant anisotropy commensurate with the microstructure of enamel which was not measurable using nanoindentation on bulk samples. The flexural strength of the enamel micro-cantilevers also exhibited strong anisotropy, and was about one order of magnitude higher than that of bulk specimens measured by three-point bending. Through a Weibull analysis, this size dependence of the strength was found to be similar to the normal behaviour in brittle materials. The flexural strength of the enamel samples was also found to be sensitive to changes in the degree of mineralization of the samples. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:375 / 383
页数:9
相关论文
共 50 条
[1]
Compositional determinants of mechanical properties of enamel [J].
Baldassarri, M. ;
Margolis, H. C. ;
Beniash, E. .
JOURNAL OF DENTAL RESEARCH, 2008, 87 (07) :645-649
[2]
Balooch M, 1998, J BIOMED MATER RES, V40, P539, DOI 10.1002/(SICI)1097-4636(19980615)40:4<539::AID-JBM4>3.0.CO
[3]
2-G
[4]
Volume effects on yield strength of equine cortical bone [J].
Bigley, R. F. ;
Gibeling, J. C. ;
Stover, S. M. ;
Hazelwood, S. J. ;
Fyhrie, D. P. ;
Martin, R. B. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2008, 1 (04) :295-302
[5]
The effect of prism orientation on the indentation testing of human molar enamel [J].
Braly, A. ;
Darnell, L. A. ;
Mann, A. B. ;
Teaford, M. F. ;
Weihs, T. P. .
ARCHIVES OF ORAL BIOLOGY, 2007, 52 (09) :856-860
[6]
Analysis of tensile bond strengths using Weibull statistics [J].
Burrow, MF ;
Thomas, D ;
Swain, MV ;
Tyas, MJ .
BIOMATERIALS, 2004, 25 (20) :5031-5035
[7]
Carvalho RM, 2000, J DENT RES, V79, P442
[8]
Measuring fracture toughness of coatings using focused-ion-beam-machined microbeams [J].
Di Maio, D ;
Roberts, SG .
JOURNAL OF MATERIALS RESEARCH, 2005, 20 (02) :299-302
[9]
Focused ion beam for microscopy and in situ sample preparation:: application on a crustacean digestive system [J].
Drobne, D ;
Milani, M ;
Ballerini, M ;
Zrimec, A ;
Berden Zrimec, M ;
Tatti, F ;
Draslar, K .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (06) :1238-1243
[10]
Surface damage induced by FIB milling and imaging of biological samples is controllable [J].
Drobne, Damjana ;
Milani, Marziale ;
Leser, Vladka ;
Tatti, Francesco .
MICROSCOPY RESEARCH AND TECHNIQUE, 2007, 70 (10) :895-903