Repeatability and reproducibility of retention data and band profiles on six batches of monolithic columns

被引:173
作者
Kele, M
Guiochon, G
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
关键词
band profiles; monolithic columns; retention data;
D O I
10.1016/S0021-9673(01)01227-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Chromatographic data were acquired for eight different mixtures, under five different sets of experimental conditions, for a total of 30 neutral, acidic and basic test compounds, on a series of six Chromolith Performance columns from Merck. These columns are made of a C-18 chemically bonded silica monolith. Each column belonged to a different production batch, so the data reported here characterize their batch-to-batch reproducibility. The parameters studied in this work were the retention times, the retention and separation factors, the hydrophobic and the steric selectivities, the column efficiencies, and the tailing factors for all 30 compounds. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:19 / 49
页数:31
相关论文
共 58 条
[1]   Sintered octadecylsilica as monolithic column packing in capillary electrochromatography and micro high-performance liquid chromatography [J].
Asiaie, R ;
Huang, X ;
Farnan, D ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1998, 806 (02) :251-263
[2]   Comparative characterization of octyl bonded phases using methylene selectivity data [J].
Bhagwat, V ;
Bereznitski, Y ;
Buszewski, B ;
Jaroniec, M .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (07) :923-939
[3]   Comparative study on the column performance of microparticulate 5-μm C18-bonded and monolithic C18-bonded reversed-phase columns in high-performance liquid chromatography [J].
Bidlingmaier, B ;
Unger, KK ;
von Doehren, N .
JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) :11-16
[4]   STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[5]  
Cabrera K, 2000, HRC-J HIGH RES CHROM, V23, P93
[6]   Retention of ionizable compounds on HPLC.: 6.: pH measurements with the glass electrode in methanol-water mixtures [J].
Canals, I ;
Oumada, FZ ;
Rosés, M ;
Bosch, E .
JOURNAL OF CHROMATOGRAPHY A, 2001, 911 (02) :191-202
[7]  
Dear G, 2001, RAPID COMMUN MASS SP, V15, P152, DOI 10.1002/1097-0231(20010130)15:2<152::AID-RCM206>3.3.CO
[8]  
2-R
[9]   Preparation and characterization of monolithic porous capillary columns loaded with chromatographic particles [J].
Dulay, MT ;
Kulkarni, RP ;
Zare, RN .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :5103-5107
[10]   SIMPLIFIED DESCRIPTION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION UNDER OVERLOAD CONDITIONS, BASED ON THE CRAIG DISTRIBUTION MODEL .2. EFFECT OF ISOTHERM TYPE, AND EXPERIMENTAL-VERIFICATION OF COMPUTER-SIMULATIONS FOR A SINGLE BAND [J].
EBLE, JE ;
GROB, RL ;
ANTLE, PE ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :45-79