Field and numerical analysis of in-situ air sparging: a case study

被引:17
作者
Benner, ML
Stanford, SM
Lee, LS
Mohtar, RH [1 ]
机构
[1] Purdue Univ, Dept Agr & Biol Engn, W Lafayette, IN 47907 USA
[2] Integrated Environm Solut, Chesterton, IN USA
[3] Purdue Univ, Dept Agron, W Lafayette, IN 47907 USA
关键词
in-situ air sparging; soil vapor collection; biodegradation; volatilization; groundwater remediation;
D O I
10.1016/S0304-3894(99)00141-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An in-situ air sparging operation was used to remediate the sandy subsurface soils and shallow groundwater under a drum storage site near Chicago, IL, where either periodic or random spillage of a light non-aqueous phase liquid (LNAPL) occurred between 1980 and 1987. Both field measurements and model simulations using commercially available computer software suggested that microbial degradation was the most significant contributor to the removal of contaminant mass. Toluene, ethylbenzene and total xylenes (TEX), which were of major concern with regards to reaching clean-up criteria at the site, were observed to decline by 88% in concentration. Furthermore, up to 97% of the total mass removed through microbial degradation consisted of TEX. Of the total contaminant spill, up to 23% of initial organic chemical mass was removed through microbial degradation compared to less than 6% by physical stripping. Greater loss to microbial degradation is most likely attributed to the relatively low air injection rate used during the-course of the air sparging remediation. Evaluation of air sparging at the site using model simulations supported this analysis by estimating 140 and 620 kg of total contaminant mass being removed through volatilization and biodegradation, respectively. An evaluation of several system design parameters using model simulations suggested that only the type of sparging operation (i.e. pulsed or continuous) was significant in terms of total contaminant removal time, while both the sparging operation and air injection rate were significant in terms of removal of a critical species, total xylenes. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:217 / 236
页数:20
相关论文
共 10 条
[1]  
BENNER ML, 1999, THESIS PURDUE U
[2]  
BOUWER H, 1978, GROUNDWATER HYDROLOG, P100
[3]  
*ENV SYST TECHN, 1998, ES T BIOVENTING US T
[4]  
*ENV SYST TECHN, 1998, ES T BIOVENTING VERS
[5]  
FEENSTRA S, 1991, GROUNDWATER MONI SPR
[6]  
Freeze A.R., 1979, GROUNDWATER
[7]  
Reinhard M., 1994, Handbook of bioremediation., P131
[8]  
STANFORD SM, 1998, THESIS PURDUE U
[9]  
U.S Environmental Protection Agency (EPA), 1986, SW846 US EPA, V1A
[10]  
*US EPA, 1996, EPA841R97008