Six-Step Operation of PMSM With Instantaneous Current Control

被引:200
作者
Kwon, Yong-Cheol [1 ]
Kim, Sungmin [1 ]
Sul, Seung-Ki [1 ]
机构
[1] Seoul Natl Univ, Power Elect Lab, Sch Elect Engn & Comp Sci, Seoul 151742, South Korea
关键词
Current control; flux weakening; motor drives; overmodulation; permanent-magnet synchronous machines (PMSMs); six-step operation; PERMANENT-MAGNET MOTOR; FLUX-WEAKENING CONTROL; VECTOR CONTROL; DRIVE SYSTEM; PERFORMANCE;
D O I
10.1109/TIA.2013.2296652
中图分类号
T [工业技术];
学科分类号
120111 [工业工程];
摘要
Six-step operation has many advantages in permanent-magnet synchronous machine (PMSM) drives such as maximum power utilization and widened flux-weakening region. However, due to the maximum utilization of inverter output, saturation of current regulator makes it difficult to maintain instantaneous current control capability. Accordingly, in most of conventional research studies, the six-step operation has been implemented by voltage angle control without current regulation, whose dynamic performance is quite unsatisfactory. This paper proposes a control scheme for the six-step operation of PMSM with enhanced dynamic performance of current control. By collaborative operation of dynamic overmodulation, flux weakening, and a technique for enhanced dynamic performance, the six-step operation is realized without losing instantaneous current control capability. Simulations and experiments are carried out to verify the effectiveness of the proposed control scheme. The experimental results show 17% extension of the constant torque region and 27% enhancement of torque capability at three times of the base speed.
引用
收藏
页码:2614 / 2625
页数:12
相关论文
共 20 条
[1]
Asano K, 2007, 2007 POWER CONVERSION CONFERENCE - NAGOYA, VOLS 1-3, P1540
[2]
Novel digital continuous control of SVM inverters in the overmodulation range [J].
Bolognani, S ;
Zigliotto, M .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (02) :525-530
[3]
A HIGH-PERFORMANCE INVERTER-FED DRIVE SYSTEM OF AN INTERIOR PERMANENT-MAGNET SYNCHRONOUS MACHINE [J].
BOSE, BK .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1988, 24 (06) :987-997
[4]
Generalized solution of minimum time current control in three-phase balanced systems [J].
Choi, JW ;
Sul, SK .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1998, 45 (05) :738-744
[5]
Carrier-based PWM-VSI overmodulation strategies: Analysis, comparison, and design [J].
Hava, AM ;
Kerkman, RJ ;
Lipo, TA .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1998, 13 (04) :674-689
[6]
Dynamic overmodulation characteristics of triangle intersection PWM methods [J].
Hava, AM ;
Sul, SK ;
Kerkman, RJ ;
Lipo, TA .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (04) :896-907
[7]
Holtz J., 1993, IEEE Transactions on Power Electronics, V8, P546, DOI 10.1109/63.261026
[8]
Speed control of interior permanent magnet synchronous motor drive for the flux weakening operation [J].
Kim, JM ;
Sul, SK .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (01) :43-48
[9]
Novel antiwindup of a current regulator of a surface-mounted permanent-magnet motor for flux-weakening control [J].
Kwon, Tae-Suk ;
Sul, Seung-Ki .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2006, 42 (05) :1293-1300
[10]
Novel Flux-Weakening Control of an IPMSM for Quasi-Six-Step Operation [J].
Kwon, Tae-Suk ;
Choi, Gi-Young ;
Kwak, Mu-Shin ;
Sul, Seung-Ki .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2008, 44 (06) :1722-1731