Active shape model based segmentation of abdominal aortic aneurysms in CTA images

被引:31
作者
de Bruijne, M [1 ]
van Ginneken, B [1 ]
Niessen, WJ [1 ]
Maintz, JBA [1 ]
Viergever, MA [1 ]
机构
[1] Univ Utrecht, Ctr Med, Image Sci Inst, Utrecht, Netherlands
来源
MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3 | 2002年 / 4684卷
关键词
Active Shape Model; image segmentation; contour matching; CT; abdominal aortic aneurysm; blood vessels;
D O I
10.1117/12.467188
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An automated method for the segmentation of thrombus in abdominal aortic aneurysms from CTA data is presented. The method is based on Active Shape Model (ASM) fitting in sequential slices, using the contour obtained in one slice as the initialisation in the adjacent slice. The optimal fit is defined by maximum correlation of grey value profiles around the contour in successive slices, in contrast to the original ASM scheme as proposed by Cootes and Taylor,(1) where the correlation with profiles from training data is maximised. An extension to the proposed approach prevents the inclusion of low-intensity tissue and allows the model to refine to nearby edges. The applied shape models contain either one or two image slices, the latter explicitly restricting the shape change from slice to slice. To evaluate the proposed methods a leave-one-out experiment was performed, using six datasets containing 274 slices to segment. Both adapted ASM schemes yield significantly better results than the original scheme (p <0.0001). The extended slice correlation fit of a one-slice model showed best overall performance. Using one manually delineated image slice as a reference, on average a number of 29 slices could be automatically segmented with an accuracy within the bounds of manual inter-observer variability.
引用
收藏
页码:463 / 474
页数:12
相关论文
共 22 条
[1]  
[Anonymous], 2000, STAT MODELS APPEARAN
[2]   CT-angiography of abdominal aortic aneurysms after transfemoral endovascular aneurysm management [J].
Balm, R ;
Kaatee, R ;
Blankensteijn, JD ;
Mali, WPTM ;
Eikelboom, BC .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1996, 12 (02) :182-188
[3]  
Behiels G, 1999, LECT NOTES COMPUT SC, V1679, P128
[4]   The efficacy of transfemoral endovascular aneurysm management: A study on size changes of the abdominal aorta during mid-term follow-up [J].
Broeders, IAMJ ;
Blankensteijn, JD ;
Gvakharia, A ;
May, J ;
Bell, PRF ;
Swedenborg, J ;
Collin, J ;
Eikelboom, BC .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 14 (02) :84-90
[5]   Spiral CT of abdominal aortic aneurysms: Comparison of segmentation with an automatic 3D deformable model and interactive segmentation [J].
Bulpitt, AJ ;
Berry, E .
MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 :938-946
[6]   USE OF ACTIVE SHAPE MODELS FOR LOCATING STRUCTURE IN MEDICAL IMAGES [J].
COOTES, TF ;
HILL, A ;
TAYLOR, CJ ;
HASLAM, J .
IMAGE AND VISION COMPUTING, 1994, 12 (06) :355-365
[7]   ACTIVE SHAPE MODELS - THEIR TRAINING AND APPLICATION [J].
COOTES, TF ;
TAYLOR, CJ ;
COOPER, DH ;
GRAHAM, J .
COMPUTER VISION AND IMAGE UNDERSTANDING, 1995, 61 (01) :38-59
[8]  
Cootes TF, 2001, PROC SPIE, V4322, P236, DOI 10.1117/12.431093
[9]   A mixture model for representing shape variation [J].
Cootes, TF ;
Taylor, CJ .
IMAGE AND VISION COMPUTING, 1999, 17 (08) :567-573
[10]   Semi-automatic aortic endograft localisation for post-operative evaluation of endovascular aneurysm treatment [J].
de Bruijne, M ;
Niessen, WJ ;
Maintz, JBA ;
Viergever, MA .
MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 :395-406