Comparative thermometric and electric measurements of the self-field AC losses in Ag-sheathed PbBi2223 tapes

被引:7
作者
Hughes, T [1 ]
Mahdi, AE [1 ]
Yang, Y [1 ]
Beduz, C [1 ]
机构
[1] UNIV SOUTHAMPTON, DEPT ELECT ENGN, SOUTHAMPTON SO17 1BJ, HANTS, ENGLAND
来源
PHYSICA C | 1997年 / 275卷 / 1-2期
关键词
D O I
10.1016/S0921-4534(96)00690-9
中图分类号
O59 [应用物理学];
学科分类号
摘要
A method for the thermometric measurement of the self-field AC losses of Ag-sheathed PbBi2223 tapes is described, This technique determines the loss by measuring the temperature profile associated with the losses, along the length of a vacuum insulated tape with each end maintained at a fixed base temperature. In practice the samples were placed in a vacuum capsule immersed in a liquid nitrogen bath, By ensuring the proper cryogenic conditions and with the use of a sensitive diode thermometer self-field losses between 7 mu Wm(-1) and 4 mWm(-1) have been measured, Comparisons with the electrical measurement technique show a good correspondence between the two methods. The effect, on the self field AC losses, of an inhomogenous distribution of critical current along the length of the tape is also discussed. Measurement of the frequency response of the losses show the importance of the eddy currents induced in the silver sheath. It is shown that these eddy currents are mainly due to the effect of the perpendicular component of the self field.
引用
收藏
页码:19 / 25
页数:7
相关论文
共 8 条
[1]   AC LOSSES OF AG-(BI,PB)SRCACUO-2223 TAPES IN COMBINATION OF TRANSVERSE EXTERNAL MAGNETIC-FIELD AND TRANSPORT CURRENT [J].
CISZEK, M ;
GLOWACKI, BA ;
ASHWORTH, SP ;
CAMPBELL, AM ;
EVETTS, JE .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1995, 5 (02) :709-712
[2]   Calorimetric ac loss measurements of silver sheathed Bi-2223 superconducting tapes [J].
Dolez, P ;
Aubin, M ;
Willen, D ;
Nadi, R ;
Cave, J .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1996, 9 (05) :374-378
[3]   APPARATUS FOR CALORIMETRIC MEASUREMENT OF AC LOSSES IN SUPERCONDUCTORS [J].
EIKELBOOM, JA .
CRYOGENICS, 1991, 31 (05) :363-365
[4]   MODIFIED BOIL-OFF METHOD FOR MEASURING AC LOSSES OF SUPERCONDUCTING COMPOSITES [J].
KURODA, K .
CRYOGENICS, 1986, 26 (10) :566-568
[6]  
Stoll RichardL., 1974, The analysis of eddy currents
[7]  
Wilson M.N., 1983, Superconducting Magnets
[8]   The influence of geometry on self-field AC losses of Ag sheathed PbBi2223 tapes [J].
Yang, Y ;
Hughes, T ;
Beduz, C ;
Spiller, DM ;
Scurlock, RG ;
Norris, WT .
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 1996, 256 (3-4) :378-386