Heterogeneous and homogeneous electrochemiluminoimmunoassays of hTSH at disposable oxide-covered aluminum electrodes

被引:43
作者
Kulmala, S
Håkansson, M
Spehar, AM
Nyman, A
Kankare, J
Loikas, K
Ala-Kleme, T
Eskola, J
机构
[1] Helsinki Univ Technol, Lab Inorgan & Analyt Chem, FIN-02015 Espoo, Finland
[2] Univ Turku, Lab Analyt Chem, FIN-20014 Turku, Finland
[3] Labmaster Oy, FIN-20521 Turku, Finland
关键词
electrochemiluminescence; electrogenerated chemiluminescence; hot electrons; thin insulating-film coated electrodes; immunoassay; bioaffinity assay; Tb(III) chelates;
D O I
10.1016/S0003-2670(02)00065-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Heterogeneous and homogeneous immunoassays of human thyroid stimulating hormone (hTSH) were developed on immunometric basis using aromatic Tb(III) chelates as electrochemiluminescent labels and varied types of disposable oxide-covered aluminum electrodes as the solid phase of the immunoassays. The long luminescence lifetime of the present labels allows the use of time-resolved electrochemiluminescence detection and provide the low detection limits of these labels and, thus, sensitive immunoassays. The primary antibody of immunometric immunoassays was coated upon aluminum oxide surface by physical absorption. In homogeneous immunoassays using 66 mul cell and 15 min incubation time, a linear calibration range of 0.25-324 muU/ml was obtained by applying only a single cathodic excitation pulse in the detection step of the assay. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:271 / 280
页数:10
相关论文
共 20 条
[1]   Hot electron-induced electrogenerated chemiluminescence of Ru(bpy)32+ chelate at oxide covered aluminum electrodes [J].
Ala-Kleme, T ;
Kulmala, S ;
Väre, L ;
Juhala, P ;
Helin, M .
ANALYTICAL CHEMISTRY, 1999, 71 (24) :5538-5543
[2]  
BLACKBURN GF, 1991, CLIN CHEM, V37, P1534
[3]   CRITICAL-REVIEW OF RATE CONSTANTS FOR REACTIONS OF HYDRATED ELECTRONS, HYDROGEN-ATOMS AND HYDROXYL RADICALS (.OH/.O-) IN AQUEOUS-SOLUTION [J].
BUXTON, GV ;
GREENSTOCK, CL ;
HELMAN, WP ;
ROSS, AB .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1988, 17 (02) :513-886
[4]  
Hemmila I, 1991, APPL FLUORESCENCE IM
[5]  
ITO M, 1999, IGAKU YAKUGAKU, V42, P161
[6]   NOVEL LABELING AGENTS FOR IMMUNOASSAY BY TIME-RESOLVED ELECTROGENERATED CHEMILUMINESCENCE [J].
KANKARE, J ;
KARPPI, A ;
TAKALO, H .
ANALYTICA CHIMICA ACTA, 1994, 295 (1-2) :27-35
[7]   CATHODICALLY INDUCED TIME-RESOLVED LANTHANIDE(III) ELECTROLUMINESCENCE AT STATIONARY ALUMINUM DISK ELECTRODES [J].
KANKARE, J ;
FALDEN, K ;
KULMALA, S ;
HAAPAKKA, K .
ANALYTICA CHIMICA ACTA, 1992, 256 (01) :17-28
[8]   IMMUNOASSAY BY TIME-RESOLVED ELECTROGENERATED LUMINESCENCE [J].
KANKARE, J ;
HAAPAKKA, K ;
KULMALA, S ;
NANTO, V ;
ESKOLA, J ;
TAKALO, H .
ANALYTICA CHIMICA ACTA, 1992, 266 (02) :205-212
[9]   Cathodic electrogenerated chemiluminescence of luminol at disposable oxide-covered aluminum electrodes [J].
Kulmala, S ;
Ala-Kleme, T ;
Kulmala, A ;
Papkovsky, D ;
Loikas, K .
ANALYTICAL CHEMISTRY, 1998, 70 (06) :1112-1118
[10]   X-ray irradiated sodium chloride as an excitation source for the sensitized terbium(III)-specific chemiluminescence of aromatic Tb(III) chelates in aqueous solutions [J].
Kulmala, S ;
Kulmala, A ;
Latva, M ;
Haapakka, K .
ANALYTICA CHIMICA ACTA, 1997, 347 (03) :333-350