How do atrial pacing algorithms prevent atrial arrhythmias?

被引:33
作者
Mitchell, ARJ [1 ]
Sulke, N [1 ]
机构
[1] Eastbourne Gen Hosp, Dept Cardiol, Eastbourne, England
来源
EUROPACE | 2004年 / 6卷 / 04期
关键词
atrial fibrillation; pacemaker; preventative pacing algorithm;
D O I
10.1016/j.eupc.2004.03.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
With an ageing population, atrial fibrillation has become an increasing cause of hospital admission and morbidity. Pacemaker implantation may prevent atrial. tachyarrhythmias by preventing bradycardia and pauses. Implantable devices are now available with specific atrial. pacing algorithms designed to prevent atrial arrhythmias. These algorithms work by increasing the atrial. pacing rate to achieve continuous overdrive pacing or by responding to triggers such as premature atrial. complexes. This article examines how the algorithms work by describing the functions of one of the new generation of pacemakers in detail. Early studies have indicated that the use of preventative pacing can reduce atrial. arrhythmia burden and symptomatic atrial. fibrillation in selected patients. There are clearly some patients who benefit from implantation of these devices but what remains unclear is how to identify this patient group. (C) 2004 The European Society of Cardiology. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:351 / 362
页数:12
相关论文
共 33 条
[1]   Relationship between selected overdrive parameters and the therapeutic outcome and tolerance of atrial overdrive pacing [J].
Attuel, P ;
Danilovic, D ;
Konz, KH ;
Brachmann, J ;
EL Allaf, D ;
Löscher, S ;
Gomes, C ;
Scheibner, T ;
Schibgilla, V ;
Szendey, I ;
Hartmann, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01) :257-263
[2]  
BARNAY C, 2002, EUROPACE, V3, P231
[3]  
CAMM AJ, 2002, PACING CLIN ELECTROP, V24, P554
[4]   Pacemaker induced mitral regurgitation: An alternative form of pacemaker syndrome [J].
Cannan, CR ;
Higano, ST ;
Holmes, DR .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (03) :735-738
[5]   A new pacemaker algorithm for the treatment of atrial fibrillation - Results of the Atrial Dynamic Overdrive Pacing Trial (ADOPT) [J].
Carlson, MD ;
Ip, J ;
Messenger, J ;
Beau, S ;
Kalbfleisch, S ;
Gervais, P ;
Cameron, DA ;
Duran, A ;
Val-Mejias, J ;
Mackall, J ;
Gold, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (04) :627-633
[6]  
DEVUSSER P, 2002, EUROPACE, V3, P244
[7]   Initiating mechanisms of paroxysmal atrial fibrillation [J].
Dimmer, C ;
Szili-Torok, T ;
Tavernier, R ;
Verstraten, T ;
Jordaens, LJ .
EUROPACE, 2003, 5 (01) :1-9
[8]   Long-short sequence may predict immediate recurrence of atrial fibrillation after external cardioversion [J].
Gorenek, B ;
Kudaiberdieva, G ;
Goktekin, O ;
Cavusoglu, Y ;
Birdane, A ;
Unalir, A ;
Ata, N ;
Timuralp, B .
EUROPACE, 2003, 5 (01) :11-16
[9]   Mechanisms of onset of atrial fibrillation:: A multicenter, prospective, pacemaker-based study [J].
Guyomar, Y ;
Thomas, O ;
Marquié, C ;
Jarwe, M ;
Klug, D ;
Kacet, S ;
Carlioz, R ;
Fossati, FDR ;
Guérin, S ;
Helus, S ;
Graux, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (06) :1336-1341
[10]  
HOFFMAN E, 2001, HEART, V83, P19