Development of novel high-sensitivity chemiluminescence assay for luminol using thiourea derivatives

被引:3
作者
Ohno, K
Arakawa, H
Yoda, R
Maeda, M [1 ]
机构
[1] Showa Univ, Sch Pharmaceut Sci, Shinagawa Ku, Tokyo 1428555, Japan
[2] Kyoritsu Coll Pharmaceut Sci, Minato Ku, Tokyo 1058512, Japan
关键词
luminol; chemiluminescence; thiourea derivative; ESR; hydroxyl radical;
D O I
10.1002/(SICI)1522-7243(199911/12)14:6<355::AID-BIO562>3.3.CO;2-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have screened about 100 thiourea derivatives in order to develop a sensitive chemiluminescence detection for luminol derivatives. Among these derivatives. we found a new compound, 2-(3-methylthioureido) thiazole, that could be used to measure luminol in the presence of hydrogen peroxide (H2O2) The detection Limits of luminol and N-(4-aminobutyl)-N-ethylisoluminol (ABEI) were 10 fmol and 100 fmol, respectively. The mechanism of proposed chemiluminescence reaction was studied by electron spin resonance (ESR) with and without superoxide dismutase (SOD) and the addition of ethanol. The results showed that 2-(3-methylthioureido) thiazole has the ability to generate hydroxyl radical from H2O2 and produces intense chemiluminescence in the presence of luminol. The proposed novel chemiluminescence reaction for luminol and luminol derivatives was applied to a high performance liquid chromatography (HPLC) assay for amino compounds. Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:355 / 360
页数:6
相关论文
共 19 条
[1]   Quantification of singlet oxygen from hematoporphyrin derivative by electron spin resonance [J].
Ando, T ;
Yoshikawa, T ;
Tanigawa, T ;
Kohno, M ;
Yoshida, N ;
Kondo, M .
LIFE SCIENCES, 1997, 61 (19) :1953-1959
[2]  
Arakawa H, 1998, J BIOLUM CHEMILUM, V13, P349, DOI 10.1002/(SICI)1099-1271(199811/12)13:6<349::AID-BIO503>3.0.CO
[3]  
2-7
[4]   CHEMI-LUMINESCENCE ENZYME IMMUNOASSAY OF CORTISOL USING PEROXIDASE AS LABEL [J].
ARAKAWA, H ;
MAEDA, M ;
TSUJI, A .
ANALYTICAL BIOCHEMISTRY, 1979, 97 (02) :248-254
[5]  
GIROTTI S, 1995, CLIN CHEM, V41, P1693
[6]   DETERMINATION OF FEMTOMOLE CONCENTRATIONS OF CATECHOLAMINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMILUMINESCENCE DETECTION [J].
HIGASHIDATE, S ;
IMAI, K .
ANALYST, 1992, 117 (12) :1863-1868
[7]   STABLE AND GENERAL-PURPOSE CHEMILUMINESCENT DETECTION SYSTEM FOR HORSERADISH-PEROXIDASE EMPLOYING A THIAZOLE COMPOUND ENHANCER AND SOME ADDITIVES [J].
IWATA, R ;
ITO, H ;
HAYASHI, T ;
SEKINE, Y ;
KOYAMA, N ;
YAMAKI, M .
ANALYTICAL BIOCHEMISTRY, 1995, 231 (01) :170-174
[8]   CHEMI-LUMINESCENCE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING N-(4-AMINOBUTYL)-N-ETHYLISOLUMINOL AS A PRECOLUMN LABELING REAGENT [J].
KAWASAKI, T ;
MAEDA, M ;
TSUJI, A .
JOURNAL OF CHROMATOGRAPHY, 1985, 328 (JUN) :121-126
[9]  
KRICKA LJ, 1991, CLIN CHEM, V37, P1472
[10]   Simultaneous detection of multiple nucleic acid targets in a homogeneous format [J].
Nelson, NC ;
BenCheikh, A ;
Matsuda, E ;
Becker, MM .
BIOCHEMISTRY, 1996, 35 (25) :8429-8438