Measurement and Quality Control Issues in Multiplex Protein Assays: A Case Study

被引:56
作者
Ellington, Allison A. [1 ]
Kullo, Iftikhar J. [1 ]
Bailey, Kent R. [2 ]
Klee, George G. [3 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN USA
[2] Mayo Clin, Dept Biostat, Rochester, MN USA
[3] Mayo Clin, Dept Lab Med & Pathol, Rochester, MN USA
关键词
IMMUNOASSAYS; MICROARRAYS; VALIDATION; PLATFORMS; PATTERNS; CANCER;
D O I
10.1373/clinchem.2008.120717
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Multiplex arrays are increasingly used for measuring protein biomarkers. Advantages of this approach include specimen conservation, limited sample handling, and decreased time and cost, but the challenges of optimizing assay format for each protein, selecting common dilution factors, and establishing robust quality control algorithms are substantial. Here, we use measurements of 15 protein biomarkers from a large study to illustrate processing, analytic, and quality control issues with multiplexed immunoassays. METHODS: We contracted with ThermoScientific for duplicate measurements of 15 proteins in 2322 participants from a community-based cohort, a plasma control, and recombinant protein controls using 2 custom planar microarrays with 6 (panel A) or 9 (panel B) capture antibodies printed in each well. We selected constituent analytes in each panel based on endogenous concentrations and assay availability. Protocols were standardized for sample processing, storage, and freeze-thaw exposures. We analyzed data for effects of deviations from processing protocols, precision, and bias. RESULTS: Measurements were within reportable ranges for each of the assays; however, concentrations for 7 of the 1.5 proteins were not centered on the dose-response curves. An additional freeze-thaw cycle and erroneous sample dilution for a subset of samples produced significantly different results. Measurements with large differences between duplicates were seen to cluster by analyte, plate, and participant. Conventional univariate quality control algorithms rejected many plates. Plate-specific medians of cohort and plasma control data significantly covaried, an observation important for development of alternative quality control algorithms. CONCLUSIONS: Multiplex measurements present difficult challenges that require further analytical and statistical developments. (C) 2009 American Association for Clinical Chemistry
引用
收藏
页码:1092 / 1099
页数:8
相关论文
共 19 条
[1]   The external RNA controls consortium: a progress report [J].
Baker, SC ;
Bauer, SR ;
Beyer, RP ;
Brenton, JD ;
Bromley, B ;
Burrill, J ;
Causton, H ;
Conley, MP ;
Elespuru, R ;
Fero, M ;
Foy, C ;
Fuscoe, J ;
Gao, XL ;
Gerhold, DL ;
Gilles, P ;
Goodsaid, F ;
Guo, X ;
Hackett, J ;
Hockett, RD ;
Ikonomi, P ;
Irizarry, RA ;
Kawasaki, ES ;
Kaysser-Kranich, T ;
Kerr, K ;
Kiser, G ;
Koch, WH ;
Lee, KY ;
Liu, CM ;
Liu, ZL ;
Lucas, A ;
Manohar, CF ;
Miyada, G ;
Modrusan, Z ;
Parkes, H ;
Puri, RK ;
Reid, L ;
Ryder, TB ;
Salit, M ;
Samaha, RR ;
Scherf, U ;
Sendera, TJ ;
Setterquist, RA ;
Shi, LM ;
Shippy, R ;
Soriano, JV ;
Wagar, EA ;
Warrington, JA ;
Williams, M ;
Wilmer, F ;
Wilson, M .
NATURE METHODS, 2005, 2 (10) :731-734
[2]  
Ball CA, 2002, SCIENCE, V298, P539
[3]  
Boerwinkle E, 2002, HYPERTENSION, V39, P3
[4]  
*END, END SEARCHLIGHT
[5]   Validation of immunoassays for bioanalysis: a pharmaceutical industry perspective [J].
Findlay, JWA ;
Smith, WC ;
Lee, JW ;
Nordblom, GD ;
Das, I ;
DeSilva, BS ;
Khan, MN ;
Bowsher, RR .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 21 (06) :1249-1273
[6]   Suspension microarrays for the identification of the response patterns in hyperinfiammatory diseases [J].
Hsu, Hsin-Yun ;
Wittemann, Silke ;
Schneider, E. Marion ;
Weiss, Manfred ;
Joos, Thomas O. .
MEDICAL ENGINEERING & PHYSICS, 2008, 30 (08) :976-983
[7]   Validating a custom multiplex ELISA against individual commercial immunoassays using clinical samples [J].
Liew, Michael ;
Groll, Matthew C. ;
Thompson, James E. ;
Call, Sara L. ;
Moser, Joann E. ;
Hoopes, Justin D. ;
Voelkerdingl, Karl ;
Wittwer, Carl ;
Spendlove, Rex S. .
BIOTECHNIQUES, 2007, 42 (03) :327-333
[8]  
*MES SCAL DISC, INSTR
[9]   Relationship between matrix metalloproteinases/tissue inhibitors of matrix metalloproteinases systems and autoantibody patterns in systemic sclerosis [J].
Montagnana, Martina ;
Volpe, Alessandro ;
Lippi, Giuseppe ;
Caramaschi, Paola ;
Salvagno, Gian Luca ;
Biasi, Domenico ;
Bambara, Lisa Maria ;
Guidi, Gian Cesare .
CLINICAL BIOCHEMISTRY, 2007, 40 (12) :837-842
[10]   Protein microarray platforms for clinical proteomics [J].
Pollard, Harvey B. ;
Srivastava, Meera ;
Eidelman, Ofer ;
Jozwik, Catherine ;
Rothwell, Stephen W. ;
Mueller, Gregory R. ;
Jacobowitz, David M. ;
Darling, Thomas ;
Guggino, William B. ;
Wright, Jerry ;
Zeitlin, Pamela L. ;
Paweletz, Cloud P. .
PROTEOMICS CLINICAL APPLICATIONS, 2007, 1 (09) :934-952