Initial study of two-phase laminar flow extraction chip for sample preparation for gas chromatography

被引:44
作者
Xiao, Hong
Liang, Dong
Liu, Guanchao
Guo, Min
Xing, Wanli
Cheng, Jing [1 ]
机构
[1] Tsing Hua Univ, Dept Biol Sci & Biotechnol, Beijing 100084, Peoples R China
[2] Tsing Hua Univ, Sch Med, Med Syst Biol Res Ctr, Beijing 100084, Peoples R China
[3] Natl Engn Res Ctr Beijing Biochip Technol, Beijing 102206, Peoples R China
[4] Tsing Hua Univ, State Key Lab Biomembrane & Membrane Biotechnol, Beijing 100084, Peoples R China
[5] CapitalBio Corp, Beijing 102206, Peoples R China
关键词
D O I
10.1039/b600374e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sample preparation method for gas chromatography using a two-phase, laminar flow extraction PDMS/glass chip has been developed. A stable two-phase laminar interface was obtained by surface modification, and the organic extraction phase and the aqueous sample phase were separated effectively when the two-phase laminar flows exit the chip. Experiments were conducted on the chip to extract ephedrine from aqueous solution. Good reproducibility was obtained over the entire range of ephedrine concentration using the extraction chips (CV range 2.7%-4.5%). Effects of salt and solvent on extraction efficiency were studied.
引用
收藏
页码:1067 / 1072
页数:6
相关论文
共 37 条
[1]  
ADAMSON AW, 1997, PHYSL CHEM SURFACES
[2]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[3]   Multiphase flows in microfluidics [J].
Baroud, CN ;
Willaime, H .
COMPTES RENDUS PHYSIQUE, 2004, 5 (05) :547-555
[4]   Miniaturized and automated sample pretreatment for determination of PCBs in environmental aqueous samples using an on-line microporous membrane liquid-liquid extraction-gas chromatography system [J].
Barri, T ;
Bergström, S ;
Norberg, J ;
Jönsson, JA .
ANALYTICAL CHEMISTRY, 2004, 76 (07) :1928-1934
[5]   Diffusion-based extraction in a microfabricated device [J].
Brody, JP ;
Yager, P .
SENSORS AND ACTUATORS A-PHYSICAL, 1997, 58 (01) :13-18
[6]   Passively driven integrated microfluidic system for separation of motile sperm [J].
Cho, BS ;
Schuster, TG ;
Zhu, XY ;
Chang, D ;
Smith, GD ;
Takayama, S .
ANALYTICAL CHEMISTRY, 2003, 75 (07) :1671-1675
[7]   A microscale-molecular weight sensor: Probing molecular diffusion between adjacent laminar flows by refractive index gradient detection [J].
Costin, CD ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 2002, 74 (17) :4558-4565
[8]  
Dean J. A., 1987, HDB ORGANIC CHEM
[9]   Ordered and disordered patterns in two-phase flows in microchannels [J].
Dreyfus, R ;
Tabeling, P ;
Willaime, H .
PHYSICAL REVIEW LETTERS, 2003, 90 (14) :4
[10]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984