Low-dose spiral CT: Application to surface-rendered three-dimensional imaging of central airways

被引:18
作者
Choi, YW
McAdams, HP
Jeon, SC
Park, CK
Lee, SJ
Kim, BS
Kim, JH
Hahm, CK
机构
[1] Hanyang Univ Hosp, Dept Radiol, Sungdong Ku, Seoul 133792, South Korea
[2] Hanyang Univ Hosp, Dept Occupat & Environm Med, Sungdong Ku, Seoul 133792, South Korea
[3] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
[4] Hanyan Univ, Kuri Hosp, Dept Radiol, Kuri, South Korea
[5] Duke Univ, Med Ctr, Dept Pathol, Durham, NC 27710 USA
关键词
computed tomography; three-dimensional; radiation exposure; comparative studies; image quality;
D O I
10.1097/00004728-200205000-00003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this work was to assess the utility of low-dose spiral CT for three-dimensional imaging of the central airways. Method: Spiral CT was performed in 15 patients using two tube currents (50 and 240 mA), producing 30 CT data sets. Surface-rendered virtual bronchoscopy (VB) and shaded surface display (SSD) images were assessed by three radiologists for image quality. The radiologists were also asked to compare 15 matched pairs each of 50 and 240 mA VB and SSD images, blindly select the 240 mA image, and record differences in diagnostic quality between the matched images. Results: No significant difference in image quality was noted with 50 or 240 mA. Only 51.1% of 240 mA SSD and 51.1% of 240 mA VB images were correctly identified. Differences in diagnostic quality, noted in 84.4% of SSD and 33% of VB image pairs, were not ascribed to image noise. Conclusion: Image quality of surface-rendered three-dimensional images of the central airways is preserved using a lower tube current.
引用
收藏
页码:335 / 341
页数:7
相关论文
共 27 条
[1]   FEASIBILITY OF HIGH-RESOLUTION, LOW-DOSE CHEST CT IN EVALUATING THE PEDIATRIC CHEST [J].
AMBROSINO, MM ;
GENIESER, NB ;
ROCHE, KJ ;
KAUL, A ;
LAWRENCE, RM .
PEDIATRIC RADIOLOGY, 1994, 24 (01) :6-10
[2]   IS CHEST CT PERFORMED TOO OFTEN [J].
DIMARCO, AF ;
BRIONES, B .
CHEST, 1993, 103 (04) :985-986
[3]   3-DIMENSIONAL IMAGING [J].
FISHMAN, EK ;
MAGID, D ;
NEY, DR ;
CHANEY, EL ;
PIZER, SM ;
ROSENMAN, JG ;
LEVIN, DN ;
VANNIER, MW ;
KUHLMAN, JE ;
ROBERTSON, DD .
RADIOLOGY, 1991, 181 (02) :321-337
[4]   THE EFFECT OF MAS VARIATION UPON COMPUTED-TOMOGRAPHY IMAGE QUALITY AS EVALUATED BY INVIVO AND INVITRO STUDIES [J].
HAAGA, JR ;
MIRALDI, F ;
MACINTYRE, W ;
LIPUMA, JP ;
BRYAN, PJ ;
WIESEN, E .
RADIOLOGY, 1981, 138 (02) :449-454
[5]   DETECTION OF BRONCHIAL ABNORMALITIES - COMPARISON OF CT AND BRONCHOSCOPY [J].
HENSCHKE, CI ;
DAVIS, SD ;
AUH, Y ;
ROMANO, P ;
WESTCOTT, J ;
BERKMEN, YM ;
KAZAM, E .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (03) :432-435
[6]   Peripheral lung cancer: Screening and detection with low-dose spiral CT versus radiography [J].
Kaneko, M ;
Eguchi, K ;
Ohmatsu, H ;
Kakinuma, R ;
Naruke, T ;
Suemasu, K ;
Moriyama, N .
RADIOLOGY, 1996, 201 (03) :798-802
[7]  
KIM N, 1998, MEDINFO, V9, P1105
[8]   3D SPIRAL CT OF THE TRACHEOBRONCHIAL TREE [J].
LACROSSE, M ;
TRIGAUX, JP ;
VANBEERS, BE ;
WEYNANTS, P .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (03) :341-347
[9]  
Lee DH, 1998, RADIOLOGY, V209P, P347
[10]   CHRONIC INFILTRATIVE LUNG-DISEASE - COMPARISON OF DIAGNOSTIC ACCURACIES OF RADIOGRAPHY AND LOW-AND CONVENTIONAL-DOSE THIN-SECTION CT [J].
LEE, KS ;
PRIMACK, SL ;
STAPLES, CA ;
MAYO, JR ;
ALDRICH, JE ;
MULLER, NL .
RADIOLOGY, 1994, 191 (03) :669-673