Iron fouling in membrane gas transfer applications

被引:8
作者
Kinnan, CM [1 ]
Johnson, DW [1 ]
机构
[1] Univ Wyoming, Dept Civil & Architectural Engn, Laramie, WY 82071 USA
关键词
fiber membranes; fouling; iron; gas and vapor permeation; water treatment;
D O I
10.1016/S0376-7388(02)00058-3
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Iron fouling characteristics of gas permeable composite and wetted microporous hollow fiber membranes were studied. Membrane modules, operated in the scaled end configuration, were pressurized with oxygen and enclosed within a tubular shell. A solution consisting of tap water and ferrous sulfate was metered though the shell side of the module. The added mass-transfer resistance due to iron fouling was determined from the required increase in oxygen feed pressure to the membranes in order to maintain constant flux across the membranes, and was evaluated as a function of operating time and process parameters. Process parameters investigated include Reynolds number, ferric and ferrous iron concentrations, iron oxidation rate, and oxygen flux. It was found that iron oxidation rate, ferric iron concentration, and oxygen flux had no impact on the rate of membrane fouling, whereas the rate and maximum extent of membrane fouling increased with Reynolds number and ferrous iron concentration. The induction period was also found to increase with Reynolds number. A maximum fouling resistance of 2779 s/cm was measured at 17 It for a Reynolds number of 9000 and ferrous iron concentration of 14.0 mg/l. This is 7.2 times greater than the overall mass-transfer resistance for the clean membrane. For all conditions in this study, constant flux across the membrane was maintained, and the impacts of fouling compensated for by operating at higher driving forces. For membrane gas transfer systems where the driving forces can be controlled, such as membrane oxygenation, driving forces can be used to compensate for increases in mass-transfer resistance. However, for applications where driving forces cannot be as easily manipulated, such as VOC stripping, iron fouling is likely to have significant impact on transfer performance. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:45 / 71
页数:27
相关论文
共 29 条
[1]   THE USE OF INDEPENDENTLY SEALED MICROPOROUS HOLLOW FIBER MEMBRANES FOR OXYGENATION OF WATER - MODEL DEVELOPMENT [J].
AHMED, T ;
SEMMENS, MJ .
JOURNAL OF MEMBRANE SCIENCE, 1992, 69 (1-2) :11-20
[2]   USE OF SEALED END HOLLOW FIBERS FOR BUBBLELESS MEMBRANE AERATION - EXPERIMENTAL STUDIES [J].
AHMED, T ;
SEMMENS, MJ .
JOURNAL OF MEMBRANE SCIENCE, 1992, 69 (1-2) :1-10
[3]   AVOIDING IRON FOULING IN REVERSE-OSMOSIS DESALINATION PLANTS [J].
APPLEGATE, LE ;
SACKINGER, CT .
DESALINATION, 1987, 61 (01) :39-48
[4]   THE CONCENTRATION AND ISOTOPIC FRACTIONATION OF OXYGEN DISSOLVED IN FRESH-WATER AND SEAWATER IN EQUILIBRIUM WITH THE ATMOSPHERE [J].
BENSON, BB ;
KRAUSE, D .
LIMNOLOGY AND OCEANOGRAPHY, 1984, 29 (03) :620-632
[5]   CaCO3 scaling in AISI 316 stainless steel tubes -: effect of thermal and hydraulic parameters on the induction time and growth rate [J].
Budair, MO ;
Khan, MS ;
Zubair, SM ;
Sheikh, AK ;
Quddus, A .
HEAT AND MASS TRANSFER, 1998, 34 (2-3) :163-170
[6]   BUBBLE-FREE AERATION USING MEMBRANES - MASS-TRANSFER ANALYSIS [J].
COTE, P ;
BERSILLON, JL ;
HUYARD, A .
JOURNAL OF MEMBRANE SCIENCE, 1989, 47 (1-2) :91-106
[7]  
DAVISON W, 1983, GEOCHIM COSMOCHIM AC, V47, P67, DOI 10.1016/0016-7037(83)90091-1
[8]   Influence of the adhesion force crystal/heat exchanger surface on fouling mitigation [J].
Förster, M ;
Augustin, W ;
Bohnet, M .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 1999, 38 (4-6) :449-461
[9]  
Franson, 1989, STANDARD METHODS EXA
[10]  
GUNTEN UV, 1991, J COLLOID INTERF SCI, V145, P127