Cardiac output measurements during cross-clamping of the descending thoracic aorta in pigs -: A comparison between transit-time ultrasound, thermodilution and pulsed Doppler ultrasound

被引:5
作者
Aadahl, P
Aakhus, S
Sæther, OD
Stomholm, T
Myhre, HO
机构
[1] Univ Trondheim Hosp, Dept Anaesthesiol, N-7006 Trondheim, Norway
[2] Univ Trondheim Hosp, Dept Med, Cardiol Sect, N-7006 Trondheim, Norway
[3] Univ Trondheim Hosp, Dept Surg, N-7006 Trondheim, Norway
关键词
cardiac output; cross-clamping; Doppler ultrasound; ketamine; thermodilution; thoracic aorta; transit-time ultrasound;
D O I
10.1034/j.1399-6576.2000.440209.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Cross-clamping of the descending thoracic aorta (XC) induces an increase in cardiac output (CO). The intention of this study was to evaluate the high CO during XC by the use of clinically available methods (thermodilution and pulsed Doppler ultrasound) compared to transit-time ultrasound flowmetry of the ascending aorta as the gold standard. Method: Ten pigs were anaesthetised with ketamine and fentanyl. The descending thoracic aorta was cross-clamped for 30 min, and cardiac output was measured with pulmonary artery thermodilution technique, pulsed Doppler ultrasound on the aortic annulus and transit-time ultrasound flowmetry of the ascending aorta. Results: At 15 min following XC, CO increased from 1.7 l/min to 4.6 l/min measured with transit-time ultrasound (P<0.05). With thermodilution technique, CO increased from 2.6 l/min to 5.7 l/min (P<0.05), and from 2.4 l/min to 6.0 l/min measured with Doppler ultrasound (P<0.05). There was an increase in mean arterial pressure of 81% and heart rate increased 76% (P<0.05). Conclusion: XC of the descending thoracic aorta induces an increase in CO of 171%. Thermodilution and pulsed Doppler ultrasound are reliable methods for detecting high cardiac output during thoracic aortic surgery.
引用
收藏
页码:180 / 185
页数:6
相关论文
共 36 条
[1]   The importance of transesophageal echocardiography during surgery of the thoracic aorta [J].
Aadahl, P ;
Saether, OD ;
Aakhus, S ;
Bjornstad, K ;
Stromholm, T ;
Myhre, HO .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1996, 12 (04) :401-406
[2]   INCREASED LEFT-VENTRICULAR CONTRACTILITY DURING CROSS-CLAMPING OF THE DESCENDING THORACIC AORTA [J].
AAKHUS, S ;
AADAHL, P ;
STROMHOLM, T ;
MYHRE, HO .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1995, 9 (05) :497-502
[3]   The explanation of the increase in systemic flow caused by occluding the descending thoracic aorta. [J].
Barcroft, H ;
Samaan, A .
JOURNAL OF PHYSIOLOGY-LONDON, 1935, 85 (01) :47-61
[4]  
BJORNSTAD K, 1993, AM J COLL CARDIOL, V21, pA371
[5]   CONTINUOUS FICK CARDIAC-OUTPUT COMPARED TO CONTINUOUS PULMONARY-ARTERY ELECTROMAGNETIC FLOW MEASUREMENT IN PIGS [J].
DAVIES, G ;
HESS, D ;
JEBSON, P .
ANESTHESIOLOGY, 1987, 66 (06) :805-809
[6]   Validation study of a new transit time ultrasonic flow probe for continuous great vessel measurements [J].
Dean, DA ;
Jia, CX ;
Cabreriza, SE ;
DAlessandro, DA ;
Dickstein, ML ;
Sardo, MJ ;
Chalik, N ;
Spotnitz, HM .
ASAIO JOURNAL, 1996, 42 (05) :M671-M676
[7]   SUPERIORITY OF END-DIASTOLIC VOLUME AND EJECTION FRACTION MEASUREMENTS OVER WEDGE PRESSURES IN EVALUATING CARDIAC-FUNCTION DURING AORTIC RECONSTRUCTION [J].
DENNIS, JW ;
MENAWAT, SS ;
SOBOWALE, OO ;
ADAMS, C ;
CRUMP, JM .
JOURNAL OF VASCULAR SURGERY, 1992, 16 (03) :372-377
[8]   COMPARISON OF PULSED DOPPLER AND THERMODILUTION METHODS FOR MEASURING CARDIAC-OUTPUT IN CRITICALLY ILL PATIENTS [J].
DONOVAN, KD ;
DOBB, GJ ;
NEWMAN, MA ;
HOCKINGS, BES ;
IRELAND, M .
CRITICAL CARE MEDICINE, 1987, 15 (09) :853-857
[9]   Measurement of cardiac output by transesophageal echocardiography in mechanically ventilated patients - Comparison with thermodilution [J].
Estagnasie, P ;
Djedaini, K ;
Mier, L ;
Coste, F ;
Dreyfuss, D .
INTENSIVE CARE MEDICINE, 1997, 23 (07) :753-759
[10]  
FANCONI S, 1992, INTENSIVE CARE WORLD, V9, P8