A framework for the merging of pre-existing and correspondenceless 3D statistical shape models

被引:9
作者
Pereanez, Marco [1 ]
Lekadir, Karim [1 ]
Butakoff, Constantine [2 ]
Hoogendoorn, Corne [1 ]
Frangi, Alejandro F. [3 ]
机构
[1] Univ Pompeu Fabra, Ctr Computat Imaging & Simulat Technol Biomed CIS, Barcelona, Spain
[2] Univ Pompeu Fabra, Sensing Physiol & Biomed PhySense, Barcelona, Spain
[3] Univ Sheffield, CISTIB, Sheffield, S Yorkshire, England
关键词
Statistical shape model; Point distribution model; Eigenspace fusion; Point correspondence; Image segmentation; PDM CONSTRUCTION; TRAINING SET; CT IMAGES; ARTIFICIAL ENLARGEMENT; DEFORMABLE MODELS; SEGMENTATION; HEART; APPEARANCE; GENERATION; FEATURES;
D O I
10.1016/j.media.2014.05.009
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The construction of statistical shape models (SSMs) that are rich, i.e., that represent well the natural and complex variability of anatomical structures, is an important research topic in medical imaging. To this end, existing works have addressed the limited availability of training data by decomposing the shape variability hierarchically or by combining statistical and synthetic models built using artificially created modes of variation. In this paper, we present instead a method that merges multiple statistical models of 3D shapes into a single integrated model, thus effectively encoding extra variability that is anatomically meaningful, without the need for the original or new real datasets. The proposed framework has great flexibility due to its ability to merge multiple statistical models with unknown point correspondences. The approach is beneficial in order to re-use and complement pre-existing SSMs when the original raw data cannot be exchanged due to ethical, legal, or practical reasons. To this end, this paper describes two main stages, i.e., (1) statistical model normalization and (2) statistical model integration. The normalization algorithm uses surface-based registration to bring the input models into a common shape parameterization with point correspondence established across eigenspaces. This allows the model fusion algorithm to be applied in a coherent manner across models, with the aim to obtain a single unified statistical model of shape with improved generalization ability. The framework is validated with statistical models of the left and right cardiac ventricles, the L1 vertebra, and the caudate nucleus, constructed at distinct research centers based on different imaging modalities (CT and MRI) and point correspondences. The results demonstrate that the model integration is statistically and anatomically meaningful, with potential value for merging pre-existing multi-modality statistical models of 3D shapes. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1044 / 1058
页数:15
相关论文
共 48 条
[1]  
[Anonymous], 2002, THESIS U MANCHESTER
[2]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[3]   A method of automated landmark generation for automated 3D PDM construction [J].
Brett, AD ;
Taylor, CJ .
IMAGE AND VISION COMPUTING, 2000, 18 (09) :739-748
[4]   A framework for weighted fusion of multiple statistical models of shape and appearance [J].
Butakoff, Constantine ;
Frangi, Alejandro F. .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2006, 28 (11) :1847-1857
[5]   ACTIVE SHAPE MODELS - THEIR TRAINING AND APPLICATION [J].
COOTES, TF ;
TAYLOR, CJ ;
COOPER, DH ;
GRAHAM, J .
COMPUTER VISION AND IMAGE UNDERSTANDING, 1995, 61 (01) :38-59
[6]   A mixture model for representing shape variation [J].
Cootes, TF ;
Taylor, CJ .
IMAGE AND VISION COMPUTING, 1999, 17 (08) :567-573
[7]  
Coxeter H., 1969, INTRO GEOM, V13
[8]  
Datar M, 2011, LECT NOTES COMPUT SC, V6892, P368, DOI 10.1007/978-3-642-23629-7_45
[9]  
Datar M, 2009, LECT NOTES COMPUT SC, V5762, P167, DOI 10.1007/978-3-642-04271-3_21
[10]   Hierarchical active shape models, using the wavelet transform [J].
Davatzikos, C ;
Tao, XD ;
Shen, DG .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (03) :414-423