Apheresis-induced platelet activation:: comparison of three types of cell separators

被引:78
作者
Hagberg, IA
Akkok, ÇA
Lyberg, T
Kjeldsen-Kragh, J
机构
[1] Ullevaal Univ Hosp, Dept Pathol, Res Forum, N-0407 Oslo, Norway
[2] Ullevaal Univ Hosp, Dept Immunol & Transfus Med, N-0407 Oslo, Norway
关键词
D O I
10.1046/j.1537-2995.2000.40020182.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Platelet-harvesting technology differs in various cell separators. Alteration in shear stress and biocompatibility of surfaces may give variable platelet activation and thereby affect the quality of the component. STUDY DESIGN AND METHODS: Four groups (n = 10) of single-needle apheresis procedures using three cell separators, were compared: 1) Spectra LRS, 90-minute harvesting time; 2) MCS+, 90-minute harvest; 3) Amicus, 90-minute; and 4) Amicus, 45-minute. Whole-blood samples were collected from the donors as were samples from the final components at intervals during the first 4 hours after cessation of the apheresis. Platelet activation status and platelet activation capacity after agonist stimulation were assessed by flow cytometry. RESULTS: No activated platelets were found in preapheresis and postapheresis samples from the donors. The platelets in the components from the Amicus (90-min) were significantly more activated than those in the other groups of components: that is, there was increased size of platelet aggregates, increased fraction of microparticles, increased degranulation, increased fibrinogen receptor activation, and decreased von Willebrand factor receptor expression. Moreover, the response of these platelets to agonist stimulation was reduced for all activation variables. CONCLUSIONS: After 90 minutes' processing time, platelets obtained with the Amicus cell separator were significantly more activated than platelets harvested with the Spectra and the MCS+.
引用
收藏
页码:182 / 192
页数:11
相关论文
共 59 条
[1]   P-selectin and platelet clearance [J].
Berger, G ;
Hartwell, DW ;
Wagner, DD .
BLOOD, 1998, 92 (11) :4446-4452
[2]   A MULTICENTER EVALUATION OF REPRODUCIBILITY OF SWIRLING IN PLATELET CONCENTRATES [J].
BERTOLINI, F ;
MURPHY, S .
TRANSFUSION, 1994, 34 (09) :796-801
[3]   Apheresis platelet concentrates: Correlation of day one levels of in vitro quality markers with corresponding levels on days two to five of storage [J].
Bessos, H ;
Atkinson, A ;
McGill, A ;
Baillie, J ;
Seghatchian, J ;
Vickers, M ;
Bishop, D ;
Tandy, N ;
Murphy, WG .
THROMBOSIS RESEARCH, 1996, 84 (05) :367-372
[4]  
BOCK M, 1995, SEMIN THROMB HEMOST, V21, P91
[5]  
BODE AP, 1991, BLOOD, V77, P887
[6]  
BRASS LF, 1993, THROMB HAEMOSTASIS, V70, P217
[7]  
Burgstaler EA, 1997, J CLIN APHERESIS, V12, P170, DOI 10.1002/(SICI)1098-1101(1997)12:4<170::AID-JCA3>3.3.CO
[8]  
2-7
[9]   Evaluation of platelet function using the in vitro bleeding time and corrected count increment of transfused platelets [J].
Eriksson, L ;
Kristensen, J ;
Olsson, K ;
Bring, J ;
Hogman, CF .
VOX SANGUINIS, 1996, 70 (02) :69-75
[10]   PLATELET CONCENTRATES IN AN ADDITIVE SOLUTION PREPARED FROM POOLED BUFFY COATS - INVIVO STUDIES [J].
ERIKSSON, L ;
SHANWELL, A ;
GULLIKSSON, H ;
HOGMAN, CF ;
SVENSSON, LA ;
KRISTENSEN, J ;
BERG, B .
VOX SANGUINIS, 1993, 64 (03) :133-138