Flow cytometric detection of HLA antibodies using a spectrum of microbeads

被引:112
作者
Pei, R
Lee, JH
Chen, T
Rojo, S
Terasaki, PI
机构
[1] One Lambda Inc, Res Dept, Canoga Park, CA USA
[2] Terasaki Fdn, Los Angeles, CA USA
关键词
HLA; antibodies; flow cytometry; microbeads; PRA;
D O I
10.1016/S0198-8859(99)00121-4
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
We describe here the use of HLA antigen coated beads for specificity and class determination of HLA antibodies by flow cytometry. The HLA specificity of antibodies was determined by use of beads containing eight levels of fluorescence. HLA antigens isolated from eight cultured cells were coated onto these beads so that each bead was the equivalent of one cell. By using Four sets of eight beads, an equivalent of 32 cells could be examined in four test tubes. A total of 76 class I and 25 class II specificities could be determined by the 32 class I bead-panel and 32 class II bead-panel used, respectively. We noted no cross-reactivity of reactions between class I and II. The sensitivity of the test was shown to be higher than that of the standard cytotoxicity by dilution experiments and detection of additional cross-reacting antigens. By use of these coated beads, we achieved improved standardized detection of HLA antibodies. Antigen-coated beads have several advantages over the use of spleens or lymphocytes. (a) A highly selected panel of antigens can be routinely used. (b) Class I and class II antibodies can be readily distinguished from each other, a en when they are present as mixtures in one serum. (c) Non-HLA antibodies are not detected because the beads do nor have any other antigens than HLA on them. (d) The quantity of antigens coated on beads is more uniform than that found in cells from different individuals. (e) Beads are more convenient for storage and daily use. (C) American Society for Histocompatibility and Immunogenetics, 1999, Published by Elsevier Science Inc.
引用
收藏
页码:1293 / 1302
页数:10
相关论文
共 36 条
  • [1] Postoperative production of anti-donor antibody and chronic rejection in renal transplantation
    Abe, M
    Kawai, T
    Futatsuyama, K
    Tanabe, K
    Fuchinoue, S
    Teraoka, S
    Toma, H
    Ota, K
    [J]. TRANSPLANTATION, 1997, 63 (11) : 1616 - 1619
  • [2] CHARACTERIZATION OF DONOR-DIRECTED ANTIBODY CLASS IN THE POSTTRANSPLANT PERIOD USING FLOW-CYTOMETRY IN RENAL-TRANSPLANTATION
    ALHUSSEIN, KA
    SHENTON, BK
    BELL, A
    TALBOT, D
    CLARK, KR
    RIGG, KM
    FORSYTHE, JLR
    PROUD, G
    TAYLOR, RMR
    [J]. TRANSPLANT INTERNATIONAL, 1994, 7 (03) : 182 - 189
  • [3] Aziz S, 1998, J HEART LUNG TRANSPL, V17, P686
  • [4] BERTELI AJ, 1992, CLIN TRANSPLANT, V6, P31
  • [5] THE FLOW CYTOMETRIC CROSSMATCH - DUAL-COLOR ANALYSIS OF T-CELL AND B-CELL REACTIVITIES
    BRAY, RA
    LEBECK, LK
    GEBEL, HM
    [J]. TRANSPLANTATION, 1989, 48 (05) : 834 - 840
  • [6] IMMUNOGLOBULIN CLASS AND SPECIFICITY OF ANTIBODIES CAUSING POSITIVE T-CELL CROSS-MATCHES - RELATIONSHIP TO RENAL-TRANSPLANT OUTCOME
    CHAPMAN, JR
    TAYLOR, CJ
    TING, A
    MORRIS, PJ
    [J]. TRANSPLANTATION, 1986, 42 (06) : 608 - 613
  • [7] Influence of anti-HLA antibodies and positive T-lymphocytotoxic crossmatch on survival and graft rejection in human liver transplantation
    Charco, R
    Vargas, V
    Balsells, J
    Lazaro, JL
    Murio, E
    Jaurrieta, E
    Martorell, J
    Margarit, C
    [J]. JOURNAL OF HEPATOLOGY, 1996, 24 (04) : 452 - 459
  • [8] Donor-specific antibodies after transplantation by flow cytometry - Relative change in fluorescence ratio most sensitive risk factor for graft survival
    Christiaans, MHL
    Overhof-deRoos, R
    Nieman, F
    Van Hooff, JP
    Van den Berg-Loonen, EM
    [J]. TRANSPLANTATION, 1998, 65 (03) : 427 - 433
  • [9] CICCIARELLI J, 1992, CLIN TRANSPLANT, V6, P159
  • [10] COOK DJ, 1987, CLIN TRANSPLANT, V1, P253