On-line ultrasonic monitoring of a die-casting process using buffer rods

被引:39
作者
Jen, CK [1 ]
Cao, B [1 ]
Nguyen, KT [1 ]
Loong, CA [1 ]
Legoux, JG [1 ]
机构
[1] MCGILL UNIV,DEPT ELECT ENGN,MONTREAL,PQ H3A 2A7,CANADA
关键词
buffer rod; die casting; on-line process monitoring; ultrasonic monitoring;
D O I
10.1016/S0041-624X(97)00015-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
On-line ultrasonic monitoring of die casting of an aluminum plate with steps of different thicknesses is studied using pulse-echo techniques. Clad buffer rods are inserted into the die wall for the monitoring. The flow front of molten aluminum inside the die has been probed by a two-channel acquisition system with a time resolution up to 1 ms. This information may be used to control the plunger movements. The gap development, due to the shrinkage of the part in the die, and the part solidification are also monitored for the understanding of the cooling process. As expected, it is observed that thicker sections take longer to solidify. The die wall temperature variation derived from the changes in ultrasonic travel time in the buffer rod is also observed. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:335 / 344
页数:10
相关论文
共 17 条
[1]  
ADDISON RC, 1994, REV PROG Q, V13, P2237
[2]  
CAO B, 1996, THESIS MCGILL U DEP
[3]  
Jen C. K., 1985, P IEEE ULTR S, P1128
[4]   FABRICATION AND CHARACTERIZATION OF CONTINUOUSLY CAST CLAD METALLIC BUFFER RODS [J].
JEN, CK ;
NERON, C ;
MIRI, A ;
SODA, H ;
OHNO, A ;
MCLEAN, A .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1992, 91 (06) :3565-3570
[5]  
JEN CK, 1996, P IEEE ULTR S, P771
[6]  
KALLIEN L, 1993, NADCA T 17 INT CAST, P85
[7]  
Konno M., 1993, P 51 ANN TECHN C SOC, P2798
[8]  
LEGOUX JG, 1996, P 9 NAT THERM SPRAY, P65
[9]  
LOHER M, 1992, DIAGRAM APR, P3
[10]  
NGUYEN KT, 1995, P 3 ANN C CFD SOC CA, V2, P167