A new continuous-flow system for the analysis of the complete stable isotopic composition of water vapor has been developed. The sample size is reduced to only 120 mug (equivalent to120 nL of liquid substance) of water, yielding precisions of about 0.7, 1.3 and 7parts per thousand for delta(17)O, delta(18)O and delta(2)H, respectively. The total time for the analysis of a sample is about 150 min including purging times. Oxidized steel surfaces can be a source of memory effects which can be corrected for. The system is predestined for atmospheric applications in the tropopause region, as the sample can be directly introduced into the system from a cryogenic trap. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:1429 / 1435
页数:7
相关论文
共 27 条
[1]   STRATOSPHERIC O-3, H2O, AND HDO DISTRIBUTIONS FROM BALLOON-BASED FAR-INFRARED OBSERVATIONS [J].
ABBAS, MM ;
GUO, J ;
CARLI, B ;
MENCARAGLIA, F ;
BONETTI, A ;
CARLOTTI, M ;
NOLT, IG .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1987, 92 (D7) :8354-8364
[2]   A new method to determine the 17O isotopic abundance in CO2 using oxygen isotope exchange with a solid oxide [J].
Assonov, SS ;
Brenninkmeijer, CAM .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (24) :2426-2437
[3]   A technique for the determination of 18O/16O and 17O/16O isotopic ratios in water from small liquid and solid samples [J].
Baker, L ;
Franchi, IA ;
Maynard, J ;
Wright, IP ;
Pillinger, CT .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1665-1673
[4]  
Bechtel C., 2003, ATMOS CHEM PHYS DISC, V3, P3991, DOI [10.5194/acpd-3-3991-2003, DOI 10.5194/acpd-3-3991-2003]
[5]   High-precision delta H-2 and delta O-18 measurement for water and volatile organic compounds by continuous-flow pyrolysis isotope ratio mass spectrometry [J].
Begley, IS ;
Scrimgeour, CM .
ANALYTICAL CHEMISTRY, 1997, 69 (08) :1530-1535
[6]  
BRENNINKMEIJER CAM, 1983, ISOT GEOSCI, V1, P181
[7]   SIMULTANEOUS MEASUREMENT OF MINOR STRATOSPHERIC CONSTITUENTS WITH EMISSION FAR-INFRARED SPECTROSCOPY [J].
CARLI, B ;
PARK, JH .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1988, 93 (D4) :3851-3865
[8]   Measurement of the isotopic ratio distribution of (HDO)-O-16 and (H2O)-O-16 in the 20-38 km altitude range from far-infrared spectra [J].
Dinelli, BM ;
Lepri, G ;
Carlotti, M ;
Carli, B ;
Mencaraglia, F ;
Ridolfi, M ;
Nolt, IG ;
Ade, PAR .
GEOPHYSICAL RESEARCH LETTERS, 1997, 24 (16) :2003-2006
[9]   MEASUREMENT OF STRATOSPHERIC DISTRIBUTIONS OF (H2O)-O-16, (H2O)-O-18, (H2O)-O-17 AND (HDO)-O-16 FROM FAR INFRARED-SPECTRA [J].
DINELLI, BM ;
CARLI, B ;
CARLOTTI, M .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1991, 96 (D4) :7509-7514
[10]   Sample preparation device for quantitative hydrogen isotope analysis using chromium metal [J].
Gehre, M ;
Hoefling, R ;
Kowski, P ;
Strauch, G .
ANALYTICAL CHEMISTRY, 1996, 68 (24) :4414-4417