High-performance liquid chromatography-ultrasonic nebulizer high-power nitrogen microwave-induced plasma mass spectrometry, real-time on-line coupling for selenium speciation analysis

被引:11
作者
Chatterjee, A
Shibata, Y
Tao, H
Tanaka, A
Morita, M
机构
[1] Natl Inst Environm Studies, Environm Chemodynam Sect, Environm Chem Div, Tsukuba, Ibaraki 3050053, Japan
[2] Natl Inst Resources & Environm, Water Anal Div, Hydrospher Environm Protect Dept, Tsukuba, Ibaraki 3058569, Japan
[3] Univ Delaware, Ctr Composite Mat, Composite Mfg Sci Lab 111, Newark, DE 19716 USA
关键词
microwave-induced plasma mass spectrometry; mass spectrometry; nebulizers; selenium compounds; organoselenium compounds;
D O I
10.1016/j.chroma.2004.05.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The coupling of a high-power nitrogen (N-2) microwave-induced plasma (MIP) mass spectrometry - (MS) (1.3 kW) with high-performance liquid chromatography, connected with concentric nebulizer (CN), ultrasonic nebulizer (USN) and a hydride generation (HG) systems, for the optimization and determination of selenium compounds, has been carried out. The MIP-MS system fulfils the ideal requirement being an on-line real-time chromatographic detector for Se speciation analysis. Interchanging of MIP-MS system fabricated nebulizer (concentric) with an ultrasonic nebulizer increases about 3.4-12 (peak height) and 6.5-10 (peak area) times ion signals for the selenium compounds. The detection limits for selenate, selenite, trimethylselenonium ion (TmSe), selenomethionine (Semet) and selenoethionine (Seet) (in Milli-Q-water) obtained with the optimized HFLC-USN-N2MIP-MS system are 0.11, 0.14, 0.09, 0.14 and 0.10 mug L-1, respectively, about 12-48 times lower than the HPLC-CN-MIP-MS and 1.5-4.4 (peak height) times lower compared to the HPLC-CN-inductively coupled plasma (ICP)-MS coupling. Considering peak area, the repeatability (R.S.D. for three successive analyses) and intermediate precision (R.S.D. for three successive analyses performed on three different days), achieved for five Se compounds are 0.8-5.6, and 1.1-5.9%, comparable with the HPLC-CN-ICP-MS, HPLC-HG-MIP-MS and HPLC-CN-MIP-MS systems. The combined HPLC-USN-N2MIP-MS has been adequately applied for the determination of Se compounds in certified National Institute for Environmental studies human urine CRM No. 18. The results reasonably agree with the HPLC-CN-ICP-MS values. This encouraging combination may be an alternative ion source of mass spectrometry for coming generation in regard to the selenium speciation analysis. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 25 条
[1]  
BURK RF, 1995, HEPATOLOGY, V21, P561
[2]   Determination of selenium compounds in urine by high-performance liquid chromatography-inductively coupled plasma mass spectrometry [J].
Chatterjee, A ;
Tao, H ;
Shibata, Y ;
Morita, M .
JOURNAL OF CHROMATOGRAPHY A, 2003, 997 (1-2) :249-257
[3]   Determination of selenite and selenomethionine by HPLC-HG-high power N2-MIP-MS:: a suitable coupling for selenium speciation [J].
Chatterjee, A ;
Shibata, Y ;
Morita, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (08) :913-919
[4]   HELIUM MICROWAVE INDUCED PLASMA MASS-SPECTROMETRY FOR DETECTION OF METALS AND NONMETALS IN AQUEOUS-SOLUTIONS [J].
CREED, JT ;
DAVIDSON, TM ;
SHEN, WL ;
BROWN, PG ;
CARUSO, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1989, 44 (09) :909-924
[5]   Determination of selenium in nickel-based alloys by flow injection hydride generation reaction cell inductively coupled plasma mass spectrometry [J].
Danadurai, KSK ;
Hsu, YL ;
Jiang, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (05) :552-555
[6]   ELEMENTAL ANALYSIS WITH A MICROWAVE-INDUCED PLASMA-QUADRUPOLE MASS-SPECTROMETER SYSTEM [J].
DOUGLAS, DJ ;
FRENCH, JB .
ANALYTICAL CHEMISTRY, 1981, 53 (01) :37-41
[7]   Selective removal of plasma matrix ions in plasma source mass spectrometry [J].
Eiden, GC ;
Barinaga, CJ ;
Koppenaal, DW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (04) :317-322
[8]   ULTRASONIC NEBULIZATION OF LIQUID SAMPLES FOR ANALYTICAL INDUCTIVELY COUPLED PLASMA-ATOMIC SPECTROSCOPY - AN UPDATE [J].
FASSEL, VA ;
BEAR, BR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (10) :1089-1113
[9]   Determination of trimethylselenonium ion in urine by ion chromatography and inductively coupled plasma mass spectrometry detection [J].
Gammelgaard, B ;
Jessen, KD ;
Kristensen, FH ;
Jons, O .
ANALYTICA CHIMICA ACTA, 2000, 404 (01) :47-54
[10]   Determination of selenite and selenate in human urine by ion chromatography and inductively coupled plasma mass spectrometry [J].
Gammelgaard, B ;
Jons, O .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (08) :945-949