Stability of atomic clocks based on entangled atoms -: art. no. 230801

被引:116
作者
André, A
Sorensen, AS
Lukin, MD
机构
[1] Harvard Univ, Dept Phys, Cambridge, MA 02138 USA
[2] Harvard Univ, Inst Theoret Atom & Mol Phys, Cambridge, MA 02138 USA
基金
美国国家科学基金会;
关键词
D O I
10.1103/PhysRevLett.92.230801
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We analyze the effect of realistic noise sources for an atomic clock consisting of a local oscillator that is actively locked to a spin-squeezed (entangled) ensemble of N atoms. We show that the use of entangled states can lead to an improvement of the long-term stability of the clock when the measurement is limited by decoherence associated with instability of the local oscillator combined with fluctuations in the atomic ensemble's Bloch vector. Atomic states with a moderate degree of entanglement yield the maximal clock stability, resulting in an improvement that scales as N-1/6 compared to the atomic shot noise level.
引用
收藏
页码:230801 / 1
页数:4
相关论文
共 23 条
[1]  
ANDRE A, UNPUB
[2]   Properties of an oscillator slaved to a periodically interrogated atomic resonator [J].
Audoin, C ;
Santarelli, G ;
Makdissi, A ;
Clairon, A .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (04) :877-886
[3]   CHARACTERIZATION OF FREQUENCY STABILITY [J].
BARNES, JA ;
CHI, AR ;
CUTLER, LS ;
HEALEY, DJ ;
LEESON, DB ;
MCGUNIGAL, TE ;
MULLEN, JA ;
SMITH, WL ;
SYDNOR, RL ;
VESSOT, RFC ;
WINKLER, GMR .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1971, IM20 (02) :105-+
[4]   Laser-cooled mercury ion frequency standard [J].
Berkeland, DJ ;
Miller, JD ;
Bergquist, JC ;
Itano, WM ;
Wineland, DJ .
PHYSICAL REVIEW LETTERS, 1998, 80 (10) :2089-2092
[5]   Optimal frequency measurements with maximally correlated states [J].
Bollinger, JJ ;
Itano, WM ;
Wineland, DJ ;
Heinzen, DJ .
PHYSICAL REVIEW A, 1996, 54 (06) :R4649-R4652
[6]  
BOUWMEESTER D, 2000, PHYS QUANTUM INFORMA
[7]   An optical clock based on a single trapped 199Hg+ ion [J].
Diddams, SA ;
Udem, T ;
Bergquist, JC ;
Curtis, EA ;
Drullinger, RE ;
Hollberg, L ;
Itano, WM ;
Lee, WD ;
Oates, CW ;
Vogel, KR ;
Wineland, DJ .
SCIENCE, 2001, 293 (5531) :825-828
[8]  
Gardiner C. W., 2000, QUANTUM NOISE
[9]   Quantum Kalman filtering and the Heisenberg limit in atomic magnetometry [J].
Geremia, JM ;
Stockton, JK ;
Doherty, AC ;
Mabuchi, H .
PHYSICAL REVIEW LETTERS, 2003, 91 (25)
[10]   A derivation of the long-term degradation of a pulsed atomic frequency standard from a control-loop model [J].
Greenhall, CA .