Optimisation of a solid-phase microextraction method for synthetic musk compounds in water

被引:65
作者
García-Jares, C [1 ]
Llompart, M [1 ]
Polo, M [1 ]
Salgado, C [1 ]
Macías, S [1 ]
Cela, R [1 ]
机构
[1] Univ Santiago de Compostela, Fac Quim, Dept Quim Analit Nutr & Bromatol, E-15706 Santiago, Spain
关键词
solid-phase microextraction; water analysis; headspace analysis; factorial design; musk compounds;
D O I
10.1016/S0021-9673(02)00649-0
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
A solid-phase microextraction method (SPME) for determining trace levels of synthetic musk fragrances in residual waters has been developed. Six polycyclic musks (cashmeran, phantolide, celestolide, traseolide, galaxolide and tonalide), and a macrocyclic musk (ambrettolide) have been analysed. A detailed study of the different parameters affecting the extraction process is presented. The main important factors affecting the microextraction process have been studied and optimised by means of a categorical factorial design. Two extraction modes (direct SPME and headspace SPME) were tried at different extraction temperatures using four different fiber coatings [polydimethylsiloxane (PDMS), Carboxen (CAR)PDMS, PDMS-divinylbenzene (DVB) and Carbowax (CW)-DVB]. An extraction temperature of 100degreesC sampling the headspace over the sample using CAR-PDMS or PDMS-DVB as fiber coatings were found to be the experimental conditions that lead to a more effective extraction. The method proposed is very simple and yields high sensitivity, with detection limits in the low pg/ml, good linearity and repeatability for all the target compounds. The total analysis time, including extraction and GC analysis, was only 45 min. The optimised method performed well when it was applied to waste water from an urban treatment plant. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:277 / 285
页数:9
相关论文
共 18 条
[1]
Results of non target screening of lipophilic organic pollutants in the German Bight II:: Polycyclic musk fragrances [J].
Bester, K ;
Hühnerfuss, H ;
Lange, W ;
Rimkus, GG ;
Theobald, N .
WATER RESEARCH, 1998, 32 (06) :1857-1863
[2]
DETERMINATION OF PHENOLS BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHIC ANALYSIS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (13) :2844-2848
[3]
Pharmaceuticals and personal care products in the environment: Agents of subtle change? [J].
Daughton, CG ;
Ternes, TA .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1999, 107 :907-938
[4]
Evaluation of musk contamination of freshwater fish in Italy by accelerated solvent extraction and gas chromatography with mass spectrometric detection [J].
Draisci, R ;
Marchiafava, C ;
Ferretti, E ;
Palleschi, L ;
Catellani, G ;
ANastasio, A .
JOURNAL OF CHROMATOGRAPHY A, 1998, 814 (1-2) :187-197
[5]
Hajslova Jana, 1998, Organohalogen Compounds, V39, P253
[6]
Heberer T, 1999, ACTA HYDROCH HYDROB, V27, P150, DOI 10.1002/(SICI)1521-401X(199905)27:3<150::AID-AHEH150>3.0.CO
[7]
2-H
[8]
Gas chromatographic determination of synthetic musk compounds in Norwegian air samples [J].
Kallenborn, R ;
Gatermann, R ;
Planting, S ;
Rimkus, GG ;
Lund, M ;
Schlabach, M ;
Burkow, IC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 846 (1-2) :295-306
[9]
Determination of tri- through heptachlorobiphenyls in water samples by SPME-GC-MS-MS:: Comparison of PDMS and PDMS-DVB coatings [J].
Landín, P ;
Llompart, M ;
Lourido, M ;
Cela, R .
JOURNAL OF MICROCOLUMN SEPARATIONS, 2001, 13 (07) :275-284
[10]
Llompart M, 2000, J MICROCOLUMN SEP, V12, P25, DOI 10.1002/(SICI)1520-667X(2000)12:1<25::AID-MCS4>3.0.CO