Fluid flow induced by nonuniform ac electric fields in electrolytes on microelectrodes.: III.: Observation of streamlines and numerical simulation -: art. no. 026305

被引:356
作者
Green, NG
Ramos, A
González, A
Morgan, H
Castellanos, A
机构
[1] Univ Glasgow, Dept Elect & Elect Engn, Bioelect Res Ctr, Glasgow G12 8LT, Lanark, Scotland
[2] Univ Seville, Fac Fis, Dept Elect & Electromagnetismo, E-41012 Seville, Spain
[3] ESI Univ Sevilla, Dept Fis Aplicada 3, Seville 41092, Spain
来源
PHYSICAL REVIEW E | 2002年 / 66卷 / 02期
关键词
D O I
10.1103/PhysRevE.66.026305
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The application of a nonuniform ac electric field to an electrolyte using coplanar microelectrodes results in steady fluid flow. The flow has its origin in the interaction of the tangential component of the nonuniform field with the induced charge in the electrical double layer on the electrode surfaces. Termed ac electro-osmosis, the flow has been studied experimentally and theoretically using linear analysis. This paper presents experimental observations of the fluid flow profile obtained by superimposing images of particle movement in a plane normal to the electrode surface. These experimental streamlines demonstrate that the fluid flow is driven at the surface of the electrodes. Experimental measurements of the impedance of the electrical double layer on the electrodes are also presented. The potential drop across the double layer at the surface of the electrodes is calculated numerically using a linear double layer model, and also using the impedance of the double layer obtained from experimental data. The ac electro-osmotic flow at the surface of the electrodes is then calculated using the Helmholtz-Smoluchowski formula. The bulk fluid flow driven by this surface velocity is numerically calculated as a function of frequency and good agreement is found between the numerical and experimental streamlines.
引用
收藏
页数:11
相关论文
共 29 条
[1]   Pumping liquids using asymmetric electrode arrays [J].
Ajdari, A .
PHYSICAL REVIEW E, 2000, 61 (01) :R45-R48
[2]   Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials [J].
Aziz-Kerrzo, M ;
Conroy, KG ;
Fenelon, AM ;
Farrell, ST ;
Breslin, CB .
BIOMATERIALS, 2001, 22 (12) :1531-1539
[3]  
Backstrom G., 1999, FLUID DYNAMICS FINIT
[4]   SURFACE-TOPOGRAPHY AND IMPEDANCE OF METAL-ELECTROLYTE INTERFACES [J].
BATES, JB ;
CHU, YT ;
STRIBLING, WT .
PHYSICAL REVIEW LETTERS, 1988, 60 (07) :627-630
[5]   Pumping of water with ac electric fields applied to asymmetric pairs of microelectrodes [J].
Brown, ABD ;
Smith, CG ;
Rennie, AR .
PHYSICAL REVIEW E, 2001, 63 (01)
[6]  
Fuhr G., 1992, Journal of Microelectromechanical Systems, V1, P141, DOI 10.1109/84.186393
[7]   Fluid flow induced by nonuniform ac electric fields in electrolytes on microelectrodes.: II.: A linear double-layer analysis [J].
González, A ;
Ramos, A ;
Green, NG ;
Castellanos, A ;
Morgan, H .
PHYSICAL REVIEW E, 2000, 61 (04) :4019-4028
[8]   Fluid flow induced by nonuniform ac electric fields in electrolytes on microelectrodes.: I.: Experimental measurements [J].
Green, NG ;
Ramos, A ;
González, A ;
Morgan, H ;
Castellanos, A .
PHYSICAL REVIEW E, 2000, 61 (04) :4011-4018
[9]   Ac electrokinetics: a survey of sub-micrometre particle dynamics [J].
Green, NG ;
Ramos, A ;
Morgan, H .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2000, 33 (06) :632-641
[10]   Electric field induced fluid flow on microelectrodes:: the effect of illumination [J].
Green, NG ;
Ramos, A ;
González, A ;
Castellanos, A ;
Morgan, H .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2000, 33 (02) :L13-L17