Morphological and hemodynamic assessments of carotid stenosis using quantitative digital subtraction angiography

被引:12
作者
Bladin, CF
Colchester, ACF
Hawkes, DJ
Seifalian, AM
Iqbal, N
Hardingham, CR
机构
[1] UNITED MED & DENT SCH,DEPT NEUROL,LONDON SE1 9RT,ENGLAND
[2] UNITED MED & DENT SCH,DIV RADIOL SCI,LONDON SE1 9RT,ENGLAND
[3] ROYAL FREE HOSP,DEPT SURG,LONDON NW3 2QG,ENGLAND
关键词
angiography; carotid stenosis; hemodynamics;
D O I
10.1161/01.STR.27.9.1672
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose Digital angiography is the best established tool for assessing atheromatous disease of extracranial blood vessels. Advances in computer technology have now made it possible and practicable to extract quantitative information (length, width, cross-sectional area, and flow velocity) from good-quality clinical angiograms, allowing calculation of volume flow and pressure gradient. The technique of quantitative angiography (QA) is used for assessing coronary artery disease, but to date there has been no clinical application in patients with cerebrovascular disease. Summary of Report We have developed a computer program for off-line analysis of routine digital subtraction angiographic images. From biplanar images, the program reconstructs the angiogram in three dimensions and performs quantitative analysis of each vessel. From this data, the pressure drop from the aortic arch to the circle of Willis is then calculated. We assessed the clinical applicability of QA in five patients investigated for transient ischemic attack. The carotid artery ipsilateral to the symptomatic hemisphere was occluded in one patient and had minor plaque in another. In the remaining three patients, ipsilateral internal carotid artery stenosis was measured by QA as producing area reductions of 55%, 72%, and 88% (equivalent to diameter reductions of 33%, 48%, and 65%, respectively). In these patients, the quantitative stenosis pressure gradients were calculated as 1.2, 3.0, and 3.5 mm Hg, respectively. Further calculation showed that each stenosis contributed to 18%, 24%, and 60%, respectively, of the total carotid pressure gradient from the aortic arch to the circle of Willis. These carotid arteries carried 47%, 42%, and 26%, respectively, of the total cerebral flow. The results of quantitative analysis were validated by comparing, within each patient, the differences in pressure gradients between right and left carotid systems or between right and left vertebral arteries (overall mean difference in pressure gradient, 0.6+/-0.5 mm Hg; P=NS). Finally, comparison was made of pressure gradients across the circle of Willis between the carotid and vertebrobasilar circulations (mean difference in pressure gradient, 4.1+/-5.3 mm Hg; P=NS). Conclusions Quantitative angiography allows determination of the hemodynamic parameters of a vessel or stenosis. It has significant potential, both as a research tool and in routine clinical practice, for the investigation of cerebrovascular disease.
引用
收藏
页码:1672 / 1678
页数:7
相关论文
共 43 条
[1]  
ACKERMAN RH, 1994, STROKE, V25, P1
[2]   MEASURING CAROTID STENOSIS - TIME FOR A REAPPRAISAL [J].
ALEXANDROV, AV ;
BLADIN, CF ;
MAGGISANO, R ;
NORRIS, JW .
STROKE, 1993, 24 (09) :1292-1296
[3]  
[Anonymous], 1991, LANCET, V337, P1235
[4]  
ARMITAGE P, 1980, STAT METHODS MED RES, P138
[5]   CAROTID ENDARTERECTOMY AND THE MEASUREMENT OF STENOSIS [J].
BARNETT, HJM ;
WARLOW, CP .
STROKE, 1993, 24 (09) :1281-1284
[6]  
BARNETT HJM, 1994, STROKE, V25, P710
[7]   CAROTID STENOSIS INDEX - A NEW METHOD OF MEASURING INTERNAL CAROTID-ARTERY STENOSIS [J].
BLADIN, CF ;
ALEXANDROV, AV ;
MURPHY, J ;
MAGGISANO, R ;
NORRIS, JW .
STROKE, 1995, 26 (02) :230-234
[8]   QUANTITATIVE CORONARY ARTERIOGRAPHY - ESTIMATION OF DIMENSIONS, HEMODYNAMIC RESISTANCE, AND ATHEROMA MASS OF CORONARY-ARTERY LESIONS USING ARTERIOGRAM AND DIGITAL COMPUTATION [J].
BROWN, BG ;
BOLSON, E ;
FRIMER, M ;
DODGE, HT .
CIRCULATION, 1977, 55 (02) :329-337
[9]  
Brunt J N, 1992, Proc Inst Mech Eng H, V206, P73, DOI 10.1243/PIME_PROC_1992_206_270_02
[10]  
BURNS PN, 1992, ULTRASOUND OBST GYN, V2, P248