Using three-dimensional difference maps to assess changes in scoliotic deformities

被引:14
作者
Berg, DC
Hill, DL [1 ]
Raso, VJ
Lou, E
Church, T
Moreau, MJ
Mahood, JK
机构
[1] Glenrose Rehabil Hosp, Capital Hlth Author, Edmonton, AB, Canada
[2] Univ Alberta, Edmonton, AB, Canada
关键词
idiopathic scoliosis; surface topography; difference map; surface matching; kyphosis; photogrammetry;
D O I
10.1007/BF02344210
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The three-dimensional nature of scoliosis, coupled with changes due to natural history or treatment, is often difficult to quantify and visualise. A difference map was developed to compare the sequential surface topography of subjects over their treatment period. Three-dimensional surface maps representing patients' trunk surfaces were captured with a laser scanner. Patient surface maps from two clinic visits were matched using a manual best-fit technique that accounted for growth and positioning. The surfaces were subtracted, generating a colour-coded three-dimensional difference map displaying the surface changes. The difference maps were compared with known clinical measures, indicating good agreement (78% specific) with the clinical parameters in detecting change. Full agreement or agreement with the clinical parameters occurred in the surgical, brace and no treatment groups: 76%, 80% and 85%, respectively. A difference index (average of the absolute value of differences on a point-by-point basis) was calculated from the difference map, enabling quantification of change. The difference index, with zero being a perfect match, averaged 5 +/- 1 for repeated measures 7 +/- 2 for subjects deemed to have no change, 9 +/- 2 for subjects with slight change, and 14 +/- 2 for subjects with significant change. The difference map showed the extent and location of changes and is a useful tool for assessing surface topography changes.
引用
收藏
页码:290 / 295
页数:6
相关论文
共 13 条
[1]   PAR CORNEAL TOPOGRAPHY SYSTEM (PAR CTS) - THE CLINICAL-APPLICATION OF CLOSE-RANGE PHOTOGRAMMETRY [J].
BELIN, MW ;
CAMBIER, JL ;
NABORS, JR ;
RATLIFF, CD .
OPTOMETRY AND VISION SCIENCE, 1995, 72 (11) :828-837
[2]   Development of a novel system for assessing tooth and restoration wear [J].
Chadwick, RG ;
Mitchell, HL ;
Cameron, I ;
Hunter, B ;
Tulley, M .
JOURNAL OF DENTISTRY, 1997, 25 (01) :41-47
[3]  
Chadwick RG, 1999, QUINTESSENCE INT, V30, P393
[4]   Conduct of an algorithm in quantifying simulated palatal surface tooth erosion [J].
Chadwick, RG ;
Mitchell, HL .
JOURNAL OF ORAL REHABILITATION, 2001, 28 (05) :450-456
[5]  
HILL DL, 2000, SERIES STUIES HLTH
[6]  
KARRAS GE, 1992, SURFACE TOPOGRAPHY AND SPINAL DEFORMITY, P162
[7]  
KARRAS GE, 1993, PHOTOGRAMM ENG REM S, V59, P1419
[8]  
KARRAS GE, 1992, INT S 3 D SCOLIOTIC, P370
[9]  
LONSTEIN JE, 1994, LANCET, V344, P1407
[10]   Mathematical shape matching as a tool in tooth wear assessment - development and conduct [J].
Mitchell, HL ;
Chadwick, RG .
JOURNAL OF ORAL REHABILITATION, 1998, 25 (12) :921-928