Chemiluminescence assay for uric acid in human serum and urine using flow-injection with immobilized reagents technology

被引:27
作者
Song, ZH [1 ]
Hou, S [1 ]
机构
[1] NW Univ Xian, Dept Chem, Xian 710069, Peoples R China
关键词
flow sensor; chemiluminescence; uric acid; urine; serum;
D O I
10.1007/s00216-001-1122-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel chemiluminescence (CL) flow sensor for the determination of uric acid in human urine and serum has been developed by using controlled-reagent-release technology. The reagents involved in the chemiluminescence (CL) reaction, luminol and periodate, are immobilized on anion-exchange resin packed in a column. After injection of water, chemiluminescence generated by released luminol and periodate in alkaline media is inhibited in presence of uric acid. By measuring the decreased chemiluminescence (CL) intensity the uric acid is sensed. The decreased response is linear in the 5.0-500.0 ng mL(-1) range, with a detection limit of 1.8 ng mL(-1). The flow sensor showed remarkable operational stability and could be easily reused for over 80 h with sampling frequency of 100 h(-1). The proposed sensor was applied to the determination of uric acid in human urine and serum, and monitoring metabolic uric acid in human urine with RSD less than 3.0%.
引用
收藏
页码:327 / 332
页数:6
相关论文
共 36 条
[1]  
Bode AM, 1999, METHOD ENZYMOL, V299, P77
[2]   Nanostructured carbon fiber disk electrodes for sensitive determinations of adenosine and uric acid [J].
Brajter-Toth, A ;
Abou El-Nour, K ;
Cavalheiro, ET ;
Bravo, R .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1576-1584
[3]  
Chen XB, 1998, J MASS SPECTROM, V33, P130, DOI 10.1002/(SICI)1096-9888(199802)33:2<130::AID-JMS616>3.0.CO
[4]  
2-Y
[5]   Quantification of urinary uric acid in the presence of thymol and thimerosal by high-performance liquid chromatography [J].
Chen, YM ;
Pietrzyk, RA ;
Whitson, PA .
JOURNAL OF CHROMATOGRAPHY A, 1997, 763 (1-2) :187-192
[6]   Sevum uric acid and cardiovascular mortality - The NHANES I epidemiologic follow-up study, 1971-1992 [J].
Fang, J ;
Alderman, MH .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 283 (18) :2404-2410
[7]  
FENREIA IMP, 1998, CARBOHYD POLYM, V37, P225
[8]   DEVELOPMENT OF AMPEROMETRIC SENSORS FOR URIC-ACID BASED ON CHEMICALLY-MODIFIED GRAPHITE-EPOXY RESIN AND SCREEN-PRINTED ELECTRODES CONTAINING COBALT PHTHALOCYANINE [J].
GILMARTIN, MAT ;
HART, JP ;
BIRCH, BJ .
ANALYST, 1994, 119 (02) :243-252
[9]  
Gong ZL, 1996, ANAL LETT, V29, P695
[10]   CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS [J].
GORTON, L .
ELECTROANALYSIS, 1995, 7 (01) :23-45