Low cost, robust, in-house hardware for heart cutting two-dimensional gas chromatography

被引:10
作者
Apps, Peter [1 ]
机构
[1] CSIR, Natl Meteorol Ctr, ZA-0001 Pretoria, South Africa
关键词
deans switch; flavours; GC-GC; heart cutting; two-dimensional;
D O I
10.1002/jssc.200600142
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Natural materials are so complex that no single column can separate all of the components. Heart cutting 2-D GC (GC-GC) using a Deans switch provides maximum separation, but the requisite gas flow configurations have earned a reputation for being fiddly and time consuming to set up and tune, unless electronic gas controls and costly software are employed. A design for a vented Deans switch is presented that can be assembled in-house from standard commercial components. A vent to atmosphere replaces the balancing resistor, which solves the problem of balancing the pressures and flows, and requires no compensation for changes in gas viscosity and back-pressure during temperature programming. First and second dimension columns can both be run at optimum flow rates, even if they are of different diameters. Analyte detectability is preserved by cutting only the target fraction from the first column and transferring the whole of it to the second column. Cryotrapping the selected fraction allows cuts of any width, and transfer of analytes to the second column as sharp bands. I have applied the vented Deans switch-cold trap to the identification of flavour and fragrance compounds from South African plants and foods; cuts are very repeatable, and the detectabiliry of trace components is enhanced. Its capabilities are demonstrated by examples from analyses of essential oils and flavour extracts.
引用
收藏
页码:2338 / 2349
页数:12
相关论文
共 44 条
[1]   Comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometric detection for the trace analysis of flavour compounds in food [J].
Adahchour, M ;
van Stee, LLP ;
Beens, J ;
Vreuls, RJJ ;
Batenburg, MA ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1019 (1-2) :157-172
[2]  
*AG TECHN, 2005, AG G2855B DEANS SWIT
[3]   Multidimensional gas chromatography using a double cool-strand interface [J].
Begnaud, F ;
Chaintreau, A .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1071 (1-2) :13-20
[4]   2-DIMENSIONAL GAS-CHROMATOGRAPHY FOR DETERMINATION OF VOLATILE COMPOUNDS IN AMBIENT AIR [J].
BERG, S ;
JONSSON, A .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1984, 7 (12) :687-695
[5]   Separation of a gasoline on an open tubular column with 1.3 million effective plates [J].
Berger, TA .
CHROMATOGRAPHIA, 1996, 42 (1-2) :63-71
[6]  
Bertsch W., 1978, Journal of High Resolution Chromatography and Chromatography Communications, V1, P289, DOI 10.1002/jhrc.1240010603
[7]  
Bertsch W, 1999, HRC-J HIGH RES CHROM, V22, P647, DOI 10.1002/(SICI)1521-4168(19991201)22:12<647::AID-JHRC647>3.0.CO
[8]  
2-V
[9]  
BERTSCH W, 1978, J HIGH RES CHROMATOG, V1, P187
[10]  
Bertsch W., 1978, J HIGH RES CHROMATOG, V1, P85