Systematic comparison of different algorithms for apnoea detection based on electrocardiogram recordings

被引:315
作者
Penzel, T [1 ]
McNames, J
de Chazal, P
Raymond, B
Murray, A
Moody, G
机构
[1] Hosp Philipps Univ, Dept Resp Crit Care Med, Marburg, Germany
[2] Portland State Univ, Portland, OR 97207 USA
[3] Univ Coll, Dept Elect & Elect Engn, Dublin, Ireland
[4] Birmingham Heartlands Hosp, Dept Resp Physiol, Birmingham, W Midlands, England
[5] Freeman Rd Hosp, Dept Reg Med Phys, Newcastle Upon Tyne, Tyne & Wear, England
[6] Harvard MIT Div Hlth Sci & Technol, Cambridge, MA USA
关键词
heart rate variability; sleep apnoea; physiologic signal database; PhysioNet; ECG; estimated respiration;
D O I
10.1007/BF02345072
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Sleep apnoea is a common disorder that is usually diagnosed through expensive studies conducted in sleep laboratories. Sleep apnoea is accompanied by a characteristic cyclic variation in heart rate or other changes in the waveform of the electrocardiogram (ECG). If sleep apnoea could be diagnosed using only the ECG, it could be possible to diagnose sleep apnoea automatically and inexpensively from ECG recordings acquired in the patient's home. This study had two parts. The first was to assess the ability of an overnight ECG recording to distinguish between patients with and without apnoea. The second was to assess whether the ECG could detect apnoea during each minute of the recording. An expert, who used additional physiological signals, assessed each of the recordings for apnoea. Research groups were invited to access data via the world-wide web and submit algorithm results to an international challenge linked to a conference. A training set of 35 recordings was made available for algorithm development, and results from a test set of 35 different recordings were made available for independent scoring. Thirteen algorithms were compared. The best algorithms made use of frequency-domain features to estimate changes in heart rate and the effect of respiration on the ECG waveform. Four of these algorithms achieved perfect scores of 100% in the first part of the study, and two achieved an accuracy of over 90% in the second part of the study.
引用
收藏
页码:402 / 407
页数:6
相关论文
共 29 条
[1]   Detection of obstructive sleep apnea through auditory display of heart rate variability [J].
Ballora, M ;
Pennycook, B ;
Ivanov, PC ;
Goldberger, A ;
Glass, L .
COMPUTERS IN CARDIOLOGY 2000, VOL 27, 2000, 27 :739-740
[2]   Automatic classification of sleep apnea epochs using the electrocardiogram [J].
de Chazal, P ;
Heneghan, C ;
Sheridan, E ;
Reilly, R ;
Nolan, P ;
O'Malley, M .
COMPUTERS IN CARDIOLOGY 2000, VOL 27, 2000, 27 :745-748
[3]   Effect of continuous positive airway pressure on blood pressure - A placebo trial [J].
Dimsdale, JE ;
Loredo, JS ;
Profant, J .
HYPERTENSION, 2000, 35 (01) :144-147
[4]   Interobserver variability in recognizing arousal in respiratory sleep disorders [J].
Drinnan, MJ ;
Murray, A ;
Griffiths, CJ ;
Gibson, GJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (02) :358-362
[5]   Detection of sleep apnoea from frequency analysis of heart rate variability [J].
Drinnan, MJ ;
Allen, J ;
Langley, P ;
Murray, A .
COMPUTERS IN CARDIOLOGY 2000, VOL 27, 2000, 27 :259-262
[6]   Sleep-related breathing disorders in adults: Recommendations for syndrome definition and measurement techniques in clinical research [J].
Flemons, WW ;
Buysse, D ;
Redline, S ;
Pack, A ;
Strohl, K ;
Wheatley, J ;
Young, T ;
Douglas, N ;
Levy, P ;
McNicholas, W ;
Fleetham, J ;
White, D ;
Schmidt-Nowarra, W ;
Carley, D ;
Romaniuk, J .
SLEEP, 1999, 22 (05) :667-689
[7]   PhysioBank, PhysioToolkit, and PhysioNet - Components of a new research resource for complex physiologic signals [J].
Goldberger, AL ;
Amaral, LAN ;
Glass, L ;
Hausdorff, JM ;
Ivanov, PC ;
Mark, RG ;
Mietus, JE ;
Moody, GB ;
Peng, CK ;
Stanley, HE .
CIRCULATION, 2000, 101 (23) :E215-E220
[8]  
GUILLEMINAULT C, 1984, LANCET, V1, P126
[9]   Evaluation of frequency and time-frequency spectral analysis of heart rate variability as a diagnostic marker of the sleep apnoea syndrome [J].
Hilton, MF ;
Bates, RA ;
Godfrey, KR ;
Chappell, MJ ;
Cayton, RM .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (06) :760-769
[10]   Apnea patients characterized by 0.02 Hz peak in the multitaper spectrogram of electrocardiogram signals [J].
Jarvis, MR ;
Mitra, PP .
COMPUTERS IN CARDIOLOGY 2000, VOL 27, 2000, 27 :769-772