Isotopic analysis of uranium and plutonium using ICP-MS and estimation of burn-up of spent uranium in contaminated environmental samples

被引:95
作者
Boulyga, SF
Becker, JS [1 ]
机构
[1] Res Ctr Julich, Cent Dept Analyt Chem, D-52425 Julich, Germany
[2] Radiat Phys & Chem Problems Inst, Minsk 220109, BELARUS
关键词
D O I
10.1039/b202196j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Environmental monitoring of actinides and evaluation of the contamination source (nuclear weapons tests, nuclear power plant and nuclear reprocessing plant accidents, etc.) requires precise and accurate isotopic analysis of actinides, especially uranium and plutonium. Double-focusing sector-field inductively coupled plasma mass spectrometry (ICP-SFMS) using a low-flow microconcentric nebulizer with membrane desolvation, "Aridus'', was applied for isotopic measurements of uranium and plutonium at the ultratrace level. The detection limit (3sigma) for U-236 and Pu-239 after chemical extraction was 0.2 pg l(-1) in aqueous solution and 0.04 pg g(-1) in soil, respectively. U-235/U-238, U-236/U-238 and Pu-240/Pu-239 isotope ratios were measured in soil samples collected within the 30 km zone around the Chernobyl nuclear power plant. The average Pu-240/Pu-239 isotope ratio in contaminated surface soil was 0.396+/-0.014. The burn-up grade and the portion of spent uranium in the spent uranium/natural uranium mixture in soil were calculated using the iteration method. A slight variation in the burn-up grade of spent reactor uranium was revealed by analyzing U-235/U-238 and U-236/U-238 isotope ratios. A relationship between the Pu-240/Pu-239 isotope ratio and burn-up of spent uranium was observed.
引用
收藏
页码:1143 / 1147
页数:5
相关论文
共 29 条