Direct determination of nucleosides in the urine of patients with breast cancer using column-switching liquid chromatography-tandem mass spectrometry

被引:47
作者
Cho, Sung-Hee
Jung, Byung Hwa
Lee, Sang Hee
Lee, Won-Yong
Kong, Gu
Chung, Bong Chul
机构
[1] Korea Inst Sci & Technol, Bioanal & Biotransformat Res Ctr, Seoul 130650, South Korea
[2] Yonsei Univ, Dept Chem, Seoul 120749, South Korea
[3] Hanyang Univ, Sch Med, Dept Pathol, Seoul 133791, South Korea
关键词
nucleosides; column-switching liquid chromatography; mass spectrometry; urine; breast cancer;
D O I
10.1002/bmc.689
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We developed an analytical method for a simple, sensitive and simultaneous determination of oxidized nucleosides in urine using column-switching liquid chromatography-electrospray/tandem mass spectrometry (LC-ESI/MS/MS). We connected two columns through a six-way switching valve and effectively separated nucleosides in the urine from the interference by column-switching liquid chromatography. We monitored separated nucleosides using positive ionization tandem mass spectrometry in selective reaction monitoring (SRM) mode. The calibration ranges of nucleosides were 0.2-100 nmol/mL. The linearity of the method was 0.994-0.999, and the limits-of-detection (LOD) at a signal-to-noise (S/N) ratio of 3 were 0.1-0.2 nmol/mL. The coefficients of variation were in the range 2.28-11.74% for within-day variation and 4.36-11.15% for day-to-day variation, respectively. To explore the relationship between breast cancer and the nucleosides level in human urine, we measured the concentrations of nucleosides in female patients with breast cancer (n = 30) and in normal female subjects (n = 30). The concentration of nucleosides was significantly increased in patients with breast cancer when compared with the normal controls (1-methyladenosine; p < 0.005, N-2,N-2-dimethylguanosine; p < 0.01, 5-hydroxymethyl-2'-deoxyuridine; p < 0.001, 8-hydroxy-2-deoxyguanosine; p < 0.001). Therefore, the elevated levels of nucleosides could be used as an important biomarker for breastcancer research. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:1229 / 1236
页数:8
相关论文
共 29 条
[1]   Alteration of 8-hydroxyguanosine concentrations in the cerebrospinal fluid and serum from patients with Parkinson's disease [J].
Abe, T ;
Isobe, C ;
Murata, T ;
Sato, C ;
Tohgi, H .
NEUROSCIENCE LETTERS, 2003, 336 (02) :105-108
[2]   Remarkable increase in the concentration of 8-hydroxyguanosine in cerebrospinal fluid from patients with Alzheimer's disease [J].
Abe, T ;
Tohgi, H ;
Isobe, C ;
Murata, T ;
Sato, C .
JOURNAL OF NEUROSCIENCE RESEARCH, 2002, 70 (03) :447-450
[3]   Content of 8-hydroxy-2-deoxyguanosine in steroid receptor-positive and receptor-negative breast cancer cells [J].
Bershtein, LM ;
Levina, VV ;
Poroshina, TE ;
Tsyrlina, EV .
BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2005, 140 (01) :88-91
[4]  
Borek E, 1972, Adv Cancer Res, V15, P163, DOI 10.1016/S0065-230X(08)60374-7
[5]  
BOREK E, 1983, RECENT RES CANCER, V84, P301
[6]  
Djuric Z, 2001, CANCER EPIDEM BIOMAR, V10, P147
[7]  
Dudley E, 2000, RAPID COMMUN MASS SP, V14, P1200, DOI 10.1002/1097-0231(20000730)14:14<1200::AID-RCM10>3.0.CO
[8]  
2-I
[9]   Discrepancies in the measurement of UVC-induced 8-oxo-2′-deoxyguanosine:: Implications for the analysis of oxidative DNA damage [J].
Evans, MD ;
Cooke, MS ;
Podmore, ID ;
Zheng, QG ;
Herbert, KE ;
Lunec, J .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1999, 259 (02) :374-378
[10]  
FISCHBEIN A, 1983, CANCER RES, V43, P2971