Objectives: In order to quantify the effects of physical activity such as walking on chronic disease, accurate measurement of physical activity is needed. The objective of this study was to determine the validity and reliability of a new activity monitor, the Fitbit One, in a population of healthy adults. Design: Cross-sectional study. Methods: Thirty healthy adults ambulated at 5 different speeds (0.90, 1.12, 1.33, 1.54, 1.78 m/s) on a treadmill while wearing three Fitbit One activity monitors (two on the hips and one in the pocket). The order of each speed condition was randomized. Fitbit One step count output was compared to observer counts and distance output was compared to the calibrated treadmill output. Two-way repeated measures ANOVA, concordance correlation coefficients, and Bland and Altman plots were used to assess validity and intra-class correlation coefficients (ICC) were used to assess reliability. Results: No significant differences were noted between Fitbit One step count outputs and observer counts, and concordance was substantial (0.97-1.00). Inter-device reliability of the step count was high for all walking speeds (ICC >= 0.95). Percent relative error was less than 1.3%. The distance output of the Fitbit One activity monitors was significantly different from the criterion values for each monitor at all speeds (P<0.001) and exhibited poor concordance (0.0-0.05). Inter-device reliability was excellent for all treadmill speeds (ICC >= 0.90). Percent relative error was high (up to 39.6%). Conclusions: The Fitbit One activity monitors are valid and reliable devices for measuring step counts in healthy young adults. The distance output of the monitors is inaccurate and should be noted with caution. (C) 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:496 / 500
页数:5
相关论文
共 22 条
[1]  
Abel MG, 2008, APPL PHYSIOL NUTR ME, V33, P1155, DOI [10.1139/h08-103, 10.1139/H08-103]
[2]   Measuring walking speed in COPD: test-retest reliability of the 30-metre walk test and comparison with the 6-minute walk test [J].
Andersson, Mikael ;
Moberg, Linda ;
Svantesson, Ulla ;
Sundbom, Ann ;
Johansson, Henrik ;
Emtner, Margareta .
PRIMARY CARE RESPIRATORY JOURNAL, 2011, 20 (04) :434-440
[3]   Physical Activity and Cancer [J].
Clague, Jessica ;
Bernstein, Leslie .
CURRENT ONCOLOGY REPORTS, 2012, 14 (06) :550-558
[4]   Spring-levered versus piezo-electric pedometer accuracy in overweight and obese adults [J].
Crouter, SE ;
Schneider, PL ;
Bassett, DR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (10) :1673-1679
[5]   The 6-min walk test - A quick measure of functional status in elderly adults [J].
Enright, PL ;
McBurnie, MA ;
Bittner, V ;
Tracy, RP ;
McNamara, R ;
Arnold, A ;
Newman, AB .
CHEST, 2003, 123 (02) :387-398
[6]   Validity of the actical accelerometer step-count function [J].
Esliger, Dale W. ;
Probert, Adam ;
Gorber, Sarah Connor ;
Bryan, Shirley ;
Laviolette, Manon ;
Tremblay, Mark S. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (07) :1200-1204
[7]   Sedentary behaviour and cardiovascular disease: a review of prospective studies [J].
Ford, Earl S. ;
Caspersen, Carl J. .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 2012, 41 (05) :1338-1353
[8]   The validity of two Omron pedometers during treadmill walking is speed dependent [J].
Giannakidou, Dimitra M. ;
Kambas, Antonis ;
Ageloussis, Nikolaos ;
Fatouros, Ioannis ;
Christoforidis, Christos ;
Venetsanou, Fotini ;
Douroudos, Ioannis ;
Taxildaris, Kyriakos .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (01) :49-57
[9]   Validity of the Omron HJ-112 Pedometer during Treadmill Walking [J].
Hasson, Rebecca E. ;
Haller, Jeannie ;
Pober, David M. ;
Staudenmayer, John ;
Freedson, Patty S. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2009, 41 (04) :805-809
[10]   Minimal Detectable Changes of the Berg Balance Scale, Fugl-Meyer Assessment Scale, Timed "Up & Go" Test, Gait Speeds, and 2-Minute Walk Test in Individuals With Chronic Stroke With Different Degrees of Ankle Plantarflexor Tone [J].
Hiengkaew, Vimonwan ;
Jitaree, Khanitha ;
Chaiyawat, Pakaratee .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (07) :1201-1208