Reprocessing of flexible endoscopes and endoscopic accessories an international comparison of guidelines

被引:14
作者
Leiss, O
Beilenhoff, U
Bader, L
Jung, M
Exner, M
机构
[1] Deutsch Klin Diagnost, Fachbereich Gastroenterol, D-65191 Wiesbaden, Germany
[2] St Hildegardis Krankenhaus, Mainz, Germany
[3] LMU Munchen, Max von Pettenkofer Inst, Munich, Germany
[4] Univ Bonn, Inst Hyg, D-5300 Bonn, Germany
来源
ZEITSCHRIFT FUR GASTROENTEROLOGIE | 2002年 / 40卷 / 07期
关键词
flexible endoscopes; reprocessing procedures; cleaning; disinfection; staff education; quality assurance; microbiological testing; hygiene;
D O I
10.1055/s-2002-32807
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Endoscopic examinations and procedures are essential for diagnosis and treatment of gastrointestinal diseases. As a result of poor reprocessing practice microorganisms can be transmitted via endoscope. The majority of infection transmissions is due to insufficient performance of cleaning and disinfection disregarding guidelines of societies of gastrointestinal endoscopy. A review of the literature and a comparison of European and American guidelines for reprocessing flexible endoscopes are given. Differences in the classification of endoscopic devices, on the possibility of prion transmission, recommendations on staff training and protection, quality assurance of reprocessing and evidence-based graduation of guidelines are stressed and discussed. With respect to the procedure of endoscope reprocessing, differences concerning the cleaning solution to choose, necessity of thoroughly manual cleaning and brushing of the accessible endoscope channels (even in the case of subsequent automatic reprocessing endoscopes in washers-disinfectors), disinfection solution, microbiological quality of water for final rinsing and rationale for alcohol flush of endoscope channels for better drying are mentioned. The need for experimental investigations of the cleaning and disinfection process is stressed. In contrast to recent guidelines of European and American societies of gastrointestinal endoscopy, the now updated recommendations of the Robert Koch-Institute for reprocessing flexible endoscopes and endoscopic accessories are evidence-based and graduated.
引用
收藏
页码:531 / 542
页数:12
相关论文
共 84 条
[1]
IN-HOSPITAL EVALUATION OF CONTAMINATION OF DUODENOSCOPES - A QUANTITATIVE ASSESSMENT OF THE EFFECT OF DRYING [J].
ALFA, MJ ;
SITTER, DL .
JOURNAL OF HOSPITAL INFECTION, 1991, 19 (02) :89-98
[2]
Worst-case soiling levels for patient-used flexible endoscopes before and after cleaning [J].
Alfa, MJ ;
Degagne, P ;
Olson, N .
AMERICAN JOURNAL OF INFECTION CONTROL, 1999, 27 (05) :392-401
[3]
PSEUDOMONAS INFECTION OF THE BILIARY SYSTEM RESULTING FROM USE OF A CONTAMINATED ENDOSCOPE [J].
ALLEN, JI ;
ALLEN, MO ;
OLSON, MM ;
GERDING, DN ;
SHANHOLTZER, CJ ;
MEIER, PB ;
VENNES, JA ;
SILVIS, SE .
GASTROENTEROLOGY, 1987, 92 (03) :759-763
[4]
Alvarado CJ, 2000, AM J INFECT CONTROL, V28, P138
[5]
*ARB END, 1995, HYG MED, V20, P40
[6]
Axon A, 2000, ENDOSCOPY, V32, P914
[7]
DISINFECTION OF ENDOSCOPIC EQUIPMENT [J].
AXON, ATR .
BAILLIERES CLINICAL GASTROENTEROLOGY, 1991, 5 (01) :61-77
[8]
Variant Creutzfeldt-Jakob disease (vCJD) and gastrointestinal endoscopy [J].
Axon, ATR ;
Beilenhoff, U ;
Bramble, MG ;
Ghosh, S ;
Kruse, A ;
McDonnell, GE ;
Neumann, C ;
Rey, JF ;
Spencer, K .
ENDOSCOPY, 2001, 33 (12) :1070-1078
[9]
Ayliffe Graham A., 1999, P881
[10]
HYGEA (Hygiene in gastroenterology endoscope reprocessing): Study on quality of reprocessing flexible endoscopes in hospitals and in the practice setting [J].
Bader, L ;
Blumenstock, G ;
Birkner, B ;
Leiss, O ;
Heesemann, J ;
Riemann, JF ;
Selbmann, HK .
ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2002, 40 (03) :157-170