Multi-Echo Acquisition of MR Angiography and Venography of the Brain at 3 Tesla

被引:45
作者
Du, Yiping P. [1 ,2 ]
Jin, Zhaoyang [3 ,4 ]
Hu, Yuzheng [5 ]
Tanabe, Jody [2 ]
机构
[1] Univ Colorado Denver, Sch Med, Brain Imaging Ctr, Dept Psychiat, Aurora, CO 80045 USA
[2] Univ Colorado Denver, Sch Med, Dept Radiol, Aurora, CO 80045 USA
[3] Zhejiang Univ, Dept Biomed Engn, Hangzhou 310003, Zhejiang, Peoples R China
[4] Hangzhou Dianzi univ, Coll Automat, Hangzhou, Zhejiang, Peoples R China
[5] Zhejiang Univ, Dept Phys, Hangzhou 310003, Zhejiang, Peoples R China
关键词
susceptibility-weighted imaging; MR venography; multi-echo acquisition; MR angiography; off-resonance artifact; time-of-flight; CONTRAST; PHASE; VESSELS; DISEASE; IMAGES; NOISE;
D O I
10.1002/jmri.21833
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To improve the visibility of veins in susceptibility-weighted imaging (SWI) using a multi-gradient echo acquisition. Materials and Methods: A three-dimensional multi-echo gradient-echo pulse sequence was developed for simultaneous acquisition of MR angiography and multiple volumes of MR venography (MRV) of the brain. The first echo was acquired for MR angiography using the time-of-flight inflow effect. The subsequent echoes were acquired for SWI-based MRV at different echo times (TEs). Results: Multiple MRV datasets acquired at different TEs were complementary in depicting the venous vasculature. MRV data acquired at a longer TE had a higher venous contrast and stronger susceptibility weighting, whereas MRV data acquired at a shorter TE had a higher signal-to-noise ratio and less severe off-resonance artifacts. Three-dimensional mapping of local field gradients was calculated and the transverse relaxivity (R(2)*) at each voxel was quantified using multi-TE exponential fitting. Conclusion: Multi-echo acquisition of MR angiography and venography demonstrated improved visibility of venous vasculature especially in regions with severe field inhomogeneity compared with conventional acquisition of. SWI and dual-echo acquisition of MR angiography and venography.
引用
收藏
页码:449 / 454
页数:6
相关论文
共 22 条
[1]   Simultaneous acquisition of MR angiography and venography (MRAV) [J].
Du, Yiping P. ;
Jin, Zhaoyang .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (05) :954-958
[2]  
Fernández-Seara MA, 2000, MAGNET RESON MED, V44, P358, DOI 10.1002/1522-2594(200009)44:3<358::AID-MRM3>3.0.CO
[3]  
2-I
[4]   INCREASED IRON-RELATED MRI CONTRAST IN THE SUBSTANTIA-NIGRA IN PARKINSONS-DISEASE [J].
GORELL, JM ;
ORDIDGE, RJ ;
BROWN, GG ;
DENIAU, JC ;
BUDERER, NM ;
HELPERN, JA .
NEUROLOGY, 1995, 45 (06) :1138-1143
[5]   Imaging iron stores in the brain using magnetic resonance imaging [J].
Haacke, EM ;
Chengb, NYC ;
House, MJ ;
Liu, Q ;
Neelavalli, J ;
Ogg, RJ ;
Khan, A ;
Ayaz, M ;
Kirsch, W ;
Obenaus, A .
MAGNETIC RESONANCE IMAGING, 2005, 23 (01) :1-25
[6]   Susceptibility weighted imaging (SWI) [J].
Haacke, EM ;
Xu, YB ;
Cheng, YCN ;
Reichenbach, JR .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) :612-618
[7]   A FAST, ITERATIVE, PARTIAL-FOURIER TECHNIQUE CAPABLE OF LOCAL PHASE RECOVERY [J].
HAACKE, EM ;
LINDSKOG, ED ;
LIN, W .
JOURNAL OF MAGNETIC RESONANCE, 1991, 92 (01) :126-145
[8]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[9]   HYBRID MR-ANGIOGRAPHY AND FOURIER VELOCITY IMAGING USING 2 ECHO 3D-ACQUISITION [J].
HOU, P ;
PARKER, DL ;
BLATTER, DD ;
ROBISON, RO .
MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (01) :203-208
[10]   Correlation of proton transverse relaxation rates (R2) with iron concentrations in postmortem brain tissue from Alzheimer's disease patients [J].
House, Michael J. ;
St Pierre, Timothy G. ;
Kowdley, Kris V. ;
Montine, Thomas ;
Connor, James ;
Beard, John ;
Berger, Jose ;
Siddaiah, Narendra ;
Shankland, Eric ;
Jin, Lee-Way .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (01) :172-180