A cylindrical Penning trap for capture, mass selective cooling, and bunching of radioactive ion beams

被引:121
作者
RaimbaultHartmann, H
Beck, D
Bollen, G
Konig, M
Kluge, HJ
Schark, E
Stein, J
Schwarz, S
Szerypo, J
机构
[1] GSI DARMSTADT,D-64220 DARMSTADT,GERMANY
[2] UNIV MAINZ,INST PHYS,D-6500 MAINZ,GERMANY
[3] UNIV WARSAW,INST EXPT PHYS,PL-00681 WARSAW,POLAND
关键词
Penning trap; mass separation; ion cooling; ion accumulation;
D O I
10.1016/S0168-583X(96)01067-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A Penning trap ion accumulator, cooler, and buncher for low-energy ion beams has been developed for the ISOLTRAP mass spectrometer at ISOLDE/CERN. A cylindrical electrode configuration is used for the creation of a nested trapping potential. This is required for efficient accumulation of externally produced ions and for high-mass selectivity by buffer gas cooling. The design goal of a mass resolving power of about 1 x 10(5) has been achieved, Isobar separation has been demonstrated for radioactive rare-earth ion beams delivered by the ISOLDE on-line mass separator.
引用
收藏
页码:378 / 382
页数:5
相关论文
共 11 条
[1]   Towards higher accuracy with the ISOLTRAP mass spectrometer [J].
Beck, D ;
Ames, F ;
Audi, G ;
Bollen, G ;
Kluge, HJ ;
Kohl, A ;
Konig, M ;
Lunney, D ;
RaimbaultHartmann, H ;
Schwarz, S ;
Szerypo, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 126 (1-4) :374-377
[2]  
BECK D, 1996, IN PRESS NUCL PHYS A
[3]   A focal plane system for the 855 MeV tagged photon spectrometer at MAMI-B [J].
Hall, SJ ;
Miller, GJ ;
Beck, R ;
Jennewein, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 368 (03) :698-708
[4]   THE ACCURACY OF HEAVY-ION MASS MEASUREMENTS USING TIME OF FLIGHT-ION CYCLOTRON-RESONANCE IN A PENNING TRAP [J].
BOLLEN, G ;
MOORE, RB ;
SAVARD, G ;
STOLZENBERG, H .
JOURNAL OF APPLIED PHYSICS, 1990, 68 (09) :4355-4374
[5]   OPEN-ENDCAP PENNING TRAPS FOR HIGH-PRECISION EXPERIMENTS [J].
GABRIELSE, G ;
HAARSMA, L ;
ROLSTON, SL .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 88 (2-3) :319-332
[6]   The REX-ISOLDE project [J].
Habs, D ;
Kester, O ;
Rudolph, K ;
Thirolf, P ;
Hinderer, G ;
Nolte, E ;
Bollen, G ;
RaimbaultHartmann, H ;
Ravn, H ;
Ames, F ;
Liljeby, L ;
Rensfelt, KG ;
Schwalm, D ;
vonHahn, R ;
Repnow, R ;
Schempp, A ;
Ratzinger, U ;
VanDuppen, P ;
Huyse, M ;
Walter, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 126 (1-4) :218-223
[7]   QUADRUPOLE EXCITATION OF STORED ION MOTION AT THE TRUE CYCLOTRON FREQUENCY [J].
KONIG, M ;
BOLLEN, G ;
KLUGE, HJ ;
OTTO, T ;
SZERYPO, J .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 142 (1-2) :95-116
[8]   THE NEW CERN-ISOLDE ONLINE MASS-SEPARATOR FACILITY AT THE PS-BOOSTER [J].
KUGLER, E ;
FIANDER, D ;
JONSON, B ;
HAAS, H ;
PRZEWLOKA, A ;
RAVN, HL ;
SIMON, DJ ;
ZIMMER, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 70 (1-4) :41-49
[9]   A NEW COOLING TECHNIQUE FOR HEAVY-IONS IN A PENNING TRAP [J].
SAVARD, G ;
BECKER, S ;
BOLLEN, G ;
KLUGE, HJ ;
MOORE, RB ;
OTTO, T ;
SCHWEIKHARD, L ;
STOLZENBERG, H ;
WIESS, U .
PHYSICS LETTERS A, 1991, 158 (05) :247-252
[10]   IN-FLIGHT CAPTURE OF IONS INTO A PENNING TRAP [J].
SCHNATZ, H ;
BOLLEN, G ;
DABKIEWICZ, P ;
EGELHOF, P ;
KERN, F ;
KALINOWSKY, H ;
SCHWEIKHARD, L ;
STOLZENBERG, H ;
KLUGE, HJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 251 (01) :17-20