Multiple solenoidal microcoil probes for high-sensitivity, high-throughput nuclear magnetic resonance spectroscopy

被引:61
作者
Li, Y
Wolters, AM
Malawey, PV
Sweedler, JV
Webb, AG
机构
[1] Univ Illinois, Dept Elect & Comp Engn, Sch Chem Sci, Urbana, IL 61801 USA
[2] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
关键词
D O I
10.1021/ac990855y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two designs for incorporating multiple solenoidal microcoils into a single probe head are presented to increase the throughput of high-resolution NMR. Through a combination of radio frequency switches and low-noise amplifiers, multiple NMR spectra can be acquired in the same time as a single spectrum from a conventional probe consisting of one coil. Since this method does not compromise sensitivity with regard to the individual microcoils, throughput increases linearly with the number of coils. Only one receiver is needed, and data acquisition parameters can be optimized for each sample. Specifically, a four-coil system has been implemented for proton NMR at 250 MHz using a wide-bore magnet, with an observe volume of 28 nL for each microcoil. Signal cross-contamination was similar to 0.2% between individual coils, and simultaneous one- and two-dimensional spectra have been obtained from samples of fructose, galactose, adenosine triphosphate, and chloroquine (7 nmol of each compound). A more compact two-coil configuration has also been designed for operation at 500 MHz, with observe volumes of 5 and 31 nL for the two coils. One- and two-dimensional spectra were acquired from samples of l-butanol (55 nmol) and ethylbenzene (250 nmol).
引用
收藏
页码:4815 / 4820
页数:6
相关论文
共 22 条
[1]   IMAGING TIME REDUCTION THROUGH MULTIPLE RECEIVER COIL DATA ACQUISITION AND IMAGE-RECONSTRUCTION [J].
CARLSON, JW ;
MINEMURA, T .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) :681-688
[2]   MULTIPLE COIL PULSED NMR METHOD FOR MEASURING THE MULTIPOLE MOMENTS OF PARTICLE ACCELERATOR BENDING MAGNETS [J].
CLARK, WG ;
HIJMANS, TW ;
WONG, WH .
JOURNAL OF APPLIED PHYSICS, 1988, 63 (08) :4185-4186
[3]   NMR probe for the simultaneous acquisition of multiple samples [J].
Fisher, G ;
Petucci, C ;
MacNamara, E ;
Raftery, D .
JOURNAL OF MAGNETIC RESONANCE, 1999, 138 (01) :160-163
[4]   Magnetic field mapping with an array of nuclear magnetic resonance probes [J].
Hammer, BE .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (06) :2378-2380
[5]   SWITCHED SURFACE COIL SYSTEM FOR BILATERAL MR IMAGING [J].
HARDY, CJ ;
KATZBERG, RW ;
FREY, RL ;
SZUMOWSKI, J ;
TOTTERMAN, S ;
MUELLER, OM .
RADIOLOGY, 1988, 167 (03) :835-838
[6]   PARALLEL IMAGE ACQUISITION FROM NONINTERACTING LOCAL COILS [J].
HYDE, JS ;
JESMANOWICZ, A ;
FRONCISZ, W ;
KNEELAND, JB ;
GRIST, TM ;
CAMPAGNA, NF .
JOURNAL OF MAGNETIC RESONANCE, 1986, 70 (03) :512-517
[7]   High-resolution NMR techniques for solid-phase synthesis and combinatorial chemistry [J].
Keifer, PA .
DRUG DISCOVERY TODAY, 1997, 2 (11) :468-478
[8]  
Keifer Paul A., 1998, Drugs of the Future, V23, P301
[9]  
MACNAMARA E, IN PRESS ANAL CHIM A
[10]   A MULTIPLE-PROBE STRATEGY FOR ULTRA-HIGH-FIELD NUCLEAR-MAGNETIC-RESONANCE SPECTROSCOPY [J].
OLDFIELD, E .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1994, 107 (02) :255-257