A randomised controlled study of the efficacy of hypromellose and Lacri-Lube combination versus polyethylene/Cling wrap to prevent corneal epithelial breakdown in the semiconscious intensive care patient

被引:71
作者
Koroloff, N
Boots, R
Lipman, J
Thomas, P
Rickard, C
Coyer, F
机构
[1] Royal Brisbane Hosp, Dept Intens Care Med, Herston, Qld 4029, Australia
[2] Queensland Univ Technol, Sch Nursing, Brisbane, Qld, Australia
[3] Univ Queensland, Dept Anaesthesiol & Crit Care, St Lucia, Qld 4067, Australia
关键词
clinical nursing research; critical care; eye; epithelium; corneal;
D O I
10.1007/s00134-004-2203-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. To compare the efficacy of two forms of eye care (hypromellose and Lacri-Lube combination vs polyethylene/Cling wrap covers) for intensive care patients. Design. Randomised-controlled trial. Setting. University affiliated, tertiary referral hospital. Patients and participants. One hundred ten patients with a reduced or absent blink reflex were followed through until they regained consciousness, were discharged from the facility during study enrolment, died or developed a positive corneal ulcer or eye infection. Interventions. All patients received standard eye cleansing every 2 h. In addition to this, group one (n=60) received a treatment combining hypromellose drops and Lacri-Lube (HL) to each eye every 2 h. Group two (n=50) had polyethylene covers only placed over the eye to create a moisture chamber. Measurements and results. Corneal ulceration was determined using corneal fluorescein stains and mobile slit lamp evaluation, performed daily. No patients had corneal ulceration in the polyethylene cover group, but 4 patients had corneal ulceration in the HL group. Conclusions. Polyethylene covers are as effective as HL in reducing the incidence of corneal damage in intensive care patients.
引用
收藏
页码:1122 / 1126
页数:5
相关论文
共 28 条
[1]   Cicatricial, postburn ectropion and exposure keratitis [J].
Astori, IP ;
Muller, MJ ;
Pegg, SP .
BURNS, 1998, 24 (01) :64-67
[2]  
BATRA YK, 1977, ANESTH ANALG, V56, P363
[3]  
BOYDMONK H, 1987, NURSING CARE EYE
[4]  
Cortese D, 1995, Am J Crit Care, V4, P425
[5]   Eyecare for the sedated patient undergoing mechanical ventilation: the use of evidence-based care [J].
Cunningham, C ;
Gould, D .
INTERNATIONAL JOURNAL OF NURSING STUDIES, 1998, 35 (1-2) :32-40
[6]  
ELLIS P, 1999, GEN OPHTHALMOLOGY, P57
[7]  
Farrell M, 1993, Intensive Crit Care Nurs, V9, P137, DOI 10.1016/0964-3397(93)90055-3
[8]  
Fleiss J. L., 1981, Statistical Methods for Rates and Proportions, V2nd
[9]  
GILBARD JP, 2000, PRINCIPLES PRACTICE, P982
[10]   Comparison of methods of eye protection under general anaesthesia [J].
Grover, VK ;
Kumar, KVM ;
Sharma, S ;
Sethi, N ;
Grewal, SPS .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (06) :575-577