Evaluation of parallel factor analysis for the resolution of kinetic data by diode-array high-performance liquid chromatography

被引:19
作者
Hindmarch, P [1 ]
Kavianpour, K [1 ]
Brereton, RG [1 ]
机构
[1] UNIV BRISTOL,SCH CHEM,BRISTOL BS8 1TS,AVON,ENGLAND
关键词
deconvolution; PARAFAC; high-performance liquid chromatography; kinetics; chlorophyll;
D O I
10.1039/a702232h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The PARAFAC algorithm for factor analysis of three or higher way datasets is summarised, A series of simulations of kinetic profiles of two-way diode-array HPLC data is described, A three-phase reaction system of reactant, intermediate and product is used to illustrate the method, each closely eluting and with similar spectra based on experimental HPLC with diode-array detection of chlorophyll degradation products. A kinetic parameter is varied to change the relative concentration of the intermediate in each series of simulations, Several indices of quality of reconstruction are introduced, It is concluded that the number of factors used to model the data is crucial to the quality of reconstruction, A good approach is first to use fewer factors than are expected, then increasing the number until each elution profile shows a single maximum.
引用
收藏
页码:871 / 877
页数:7
相关论文
共 29 条
[1]   Single measurement excitation/emission matrix spectrofluorometer for determination of hydrocarbons in ocean water .2. Calibration and quantitation of naphthalene and styrene [J].
Booksh, KS ;
Muroski, AR ;
Myrick, ML .
ANALYTICAL CHEMISTRY, 1996, 68 (20) :3539-3544
[2]  
BRERETON RG, 1993, PHOTOCHEM PHOTOBIOL, V57, P1048
[3]   Enzymatic browning of vegetables. Calibration and analysis of variance by multiway methods [J].
Bro, R ;
Heimdal, H .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 34 (01) :85-102
[4]  
Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.0.CO
[5]  
2-C
[7]   THE 3 BASIC FACTOR-ANALYTIC RESEARCH DESIGNS - THEIR INTERRELATIONS AND DERIVATIVES [J].
CATTELL, RB .
PSYCHOLOGICAL BULLETIN, 1952, 49 (05) :499-520
[8]   RESOLVABILITY INDEXES AND VARIABLE SELECTION IN FACTOR-ANALYSIS OF DIODE-ARRAY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - DEVELOPMENT OF AN APPROACH FOR MULTI-PEAK CLUSTERS AND APPLICATION TO MIXTURES OF CHLOROPHYLL DEGRADATION PRODUCTS [J].
ELBERGALI, AK ;
BRERETON, RG ;
RAHMANI, A .
ANALYST, 1995, 120 (08) :2207-2216
[9]   ANALYSIS OF MULTI-WAY (MULTI-MODE) DATA [J].
GELADI, P .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1989, 7 (1-2) :11-30
[10]   Resolution of multicomponent mixture spectra in mid-infrared spectroscopy using spherical projection factor analysis: Application to real data including a six-component mixture set [J].
Gurden, SP ;
Brereton, RG ;
Groves, JA .
ANALYST, 1996, 121 (04) :441-450